Chest radiographic image quality: comparison of asymmetric screen-film, digital storage phosphor, and digital selenium drum systems--preliminary study.

G H Beute1, M J Flynn, W R Eyler, E Samei, D L Spizarny, C J Zylak.   

Abstract

Conventional screen-film radiography does not display all regions of the thorax satisfactorily. Three chest radiographic techniques display both the lung and the mediastinum with good contrast. These techniques are asymmetric screen-film (ASF), digital storage phosphor (DSP), and digital selenium drum (DSD) imaging. ASF systems use two asymmetric screen-film combinations to produce a wide-latitude image of the thorax with good contrast in the lungs. In DSP systems, image data are acquired digitally with a wide dynamic range by using the optical output of a photostimulable phosphor plate; in DSD systems, the wide-range digital image data are acquired by using the electronic charge generated on a drum coated with a thin layer of amorphous selenium. The appearance of a DSP or DSD radiograph is then determined by user-selected image processing operations: tone scaling, spatial frequency processing, and dynamic range compensation. Digital chest radiographs processed with strong regional equalization provide both excellent contrast in the lungs and effective display of the mediastinum and chest wall. At visual comparison, the high lung contrast and good mediastinal, retrocardiac, and subdiaphragmatic detail provided by the DSD method distinguish it from the other two methods.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9599395     DOI: 10.1148/radiographics.18.3.9599395

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  2 in total

1.  Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Mireille V Boot; Bart J A Mertens; Jacob Geleijns
Journal:  Eur Radiol       Date:  2005-08-31       Impact factor: 5.315

2.  Interpretation of normal anatomic structures on chest radiography: comparison of Fuji computed radiography (FCR) 5501D with FCR 5000 and screen-film system.

Authors:  Kazuaki Nakashima; Kazuto Ashizawa; Makoto Ochi; Rashid Hashmi; Kuniaki Hayashi; Shinichi Gotoh; Sumihisa Honda; Akito Igarashi; Takao Komaki
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.