Literature DB >> 9599035

Engineering the tissue which encapsulates subcutaneous implants. II. Plasma-tissue exchange properties.

A A Sharkawy1, B Klitzman, G A Truskey, W M Reichert.   

Abstract

This study assesses the plasma-tissue exchange characteristics of the capsular tissue that forms around implants and how they are affected by implant porosity. The number of vessels and their permeability to rhodamine were measured by intravascular injection of the fluorophore tracer into Sprague-Dawley rats that hosted for 3-4 months polyvinyl alcohol (PVA) and polytetrafluoroethylene (PTFE) subcutaneous implants. Rats were implanted with four pore sizes of PVA--a nonporous PVA (PVA-skin), and 5, 60, and 700 micron mean pore sizes (PVA-5, PVA-60, and PVA-700, respectively)--and two pore sizes of PTFE: 0.50 (PTFE-0.5) and 5.0 (PTFE-5) mean micron pore sizes. Photodensitometric image analysis was used to quantify the local tracer extravasation and, hence the permeability coefficients of isolated vessels around the implants. The number of functional vessels within 100 microm of the implants highlighted by the lissamine-rhodamine tracer were counted with fluorescence microscopy and with H&E stained sections using brightfield microscopy. The permeability of vessels did not vary substantially with implant pore size but generally were lower than those measured for surrounding subcutis. Pore size, however, had a dramatic effect on the vascular density of tissue-encapsulating implants: the number of microvessels (under 10 microm in radius) within the tissue surrounding the porous implants was higher than the number around nonporous implants. Pore sizes on the order of cellular dimensions incited optimal neovascularization; the vascular density around PVA-60 implants was six times higher (p < .001) and three times higher (p < .001) than those around PVA-0 implants in the fluorescent images and in brightfield, respectively. Moreover, brightfield microscopy showed the number of vessels around PVA-60 implants was almost double those in normal subcutis. The results suggest that optimal vascular density around long-term implants, such as sensors, biofluid cell constructs, and immunoisolated cell systems, may be engineered with pore size.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9599035     DOI: 10.1002/(sici)1097-4636(19980615)40:4<586::aid-jbm10>3.0.co;2-e

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  45 in total

1.  On the formation of fibrous capsule and fluid space around machined and porous blood plasma clot coated titanium.

Authors:  E Jansson; M Källtorp; A Johansson; P Tengvall; P Thomsen
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

2.  Glucose sensor membranes for mitigating the foreign body response.

Authors:  Ahyeon Koh; Scott P Nichols; Mark H Schoenfisch
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

Review 3.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

4.  Bioluminescence imaging of glucose in tissue surrounding polyurethane and glucose sensor implants.

Authors:  Heather L Prichard; Thies Schroeder; William M Reichert; Bruce Klitzman
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

5.  Biomaterial topography alters healing in vivo and monocyte/macrophage activation in vitro.

Authors:  Paige C S Bota; Angela M B Collie; Pauli Puolakkainen; Robert B Vernon; E Helene Sage; Buddy D Ratner; Patrick S Stayton
Journal:  J Biomed Mater Res A       Date:  2010-11       Impact factor: 4.396

6.  Prevascularized silicon membranes for the enhancement of transport to implanted medical devices.

Authors:  Kristan S Worthington; Luke A Wiley; Robert F Mullins; Budd A Tucker; Eric Nuxoll
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-08-28       Impact factor: 3.368

Review 7.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

Review 8.  Manipulating the microvasculature and its microenvironment.

Authors:  Laxminarayanan Krishnan; Carlos C Chang; Sara S Nunes; Stuart K Williams; Jeffrey A Weiss; James B Hoying
Journal:  Crit Rev Biomed Eng       Date:  2013

9.  [STARflo-a suprachoroidal drainage implant in glaucoma surgery].

Authors:  S König; C W Hirneiß
Journal:  Ophthalmologe       Date:  2018-08       Impact factor: 1.059

10.  In vitro and in vivo characterization of porous poly-L-lactic acid coatings for subcutaneously implanted glucose sensors.

Authors:  H E Koschwanez; F Y Yap; B Klitzman; W M Reichert
Journal:  J Biomed Mater Res A       Date:  2008-12-01       Impact factor: 4.396

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.