Literature DB >> 9597582

Comparative analysis of below-knee prosthetic socket liner materials.

R Emrich1, K Slater.   

Abstract

Four materials used in lining prosthetic sockets were compared for their potential usefulness in below-knee applications. Tests carried out included determinations of resistance to compression, resistance to flexural abrasion and coefficients (static and dynamic) of friction. These tests were designed, respectively, to assess changes occurring during end-use brought about by extensive application of compressive or shear force, and to predict the ability to retain contact with the body and socket. Of the four materials in the study (Bock-Lite, Pedilin, polyurethane and silicone), Bock-Lite and silicone had high compression resistance, Bock-Lite had good resistance to flexural abrasion, and polyurethane and silicone had high coefficients of frictional resistance. Thus, Bock-Lite will be the most durable of the four materials but, since it had the lowest frictional coefficient, it may slip in use. Conversely, silicone and polyurethane, which will be retained in position more easily, are easily torn or compressed, so are likely to need replacement more frequently.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9597582     DOI: 10.3109/03091909809010005

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  5 in total

1.  Development of Standardized Material Testing Protocols for Prosthetic Liners.

Authors:  John C Cagle; Per G Reinhall; Brian J Hafner; Joan E Sanders
Journal:  J Biomech Eng       Date:  2017-04-01       Impact factor: 2.097

2.  Elastomeric liners for people with transtibial amputation: Survey of prosthetists' clinical practices.

Authors:  Brian J Hafner; John C Cagle; Katheryn J Allyn; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2016-09-24       Impact factor: 1.895

Review 3.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

4.  Thermal time constant: optimising the skin temperature predictive modelling in lower limb prostheses using Gaussian processes.

Authors:  Neha Mathur; Ivan Glesk; Arjan Buis
Journal:  Healthc Technol Lett       Date:  2016-05-20

5.  Application of a mechanobiological algorithm to investigate mechanical mediation of heterotopic bone in trans-femoral amputees.

Authors:  Naomi M Rosenberg; Anthony M J Bull
Journal:  Sci Rep       Date:  2018-09-21       Impact factor: 4.379

  5 in total