Toroidal coil counter-current chromatography study of the mass transfer rate of proteins in aqueous-aqueous polymer phase system.

Y Ito1, K Matsuda, Y Ma, L Qi.   

Abstract

The cause of excessive band broadening of protein samples in polymer phase partitioning by counter-current chromatography (CCC) was investigated. A simple rotary device was constructed to measure the mass transfer rates of five samples including potassium dichromate, methylene blue, lysozyme, ovalbumin and human serum albumin. The results indicated that the mass transfer rates of these samples are closely correlated with their molecular masses: the higher the molecular mass, the lower the mass transfer rate. These findings are also consistent with the partition efficiencies of these samples in the same solvent system by CCC. The beneficial effect of the Coriolis force demonstrated in protein separations by the toroidal coil centrifuge may be reasonably explained on the basis of the mass transfer resistance of protein molecules through the interface: we speculate that when the Coriolis force acts parallel to the effective coil segment it can produce large interfacial areas by dispersing the mobile phase into the stationary phase, thus accelerating the mass transfer rate of protein samples.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9595695     DOI: 10.1016/s0021-9673(97)01171-0

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography.

Authors:  Yi Yang; Dongyu Gu; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2011-10-25       Impact factor: 3.205

2.  A simple tool for tubing modification to improve spiral high-speed counter-current chromatography for protein purification.

Authors:  Yoichiro Ito; Xiaofeng Ma; Robert Clary
Journal:  Curr Chromatogr       Date:  2016

3.  Studies on the effect of column angle in figure-8 centrifugal counter-current chromatography.

Authors:  Yi Yang; Dongyu Gu; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2010-11-21       Impact factor: 4.759

4.  Spiral column configuration for protein separation by high-speed countercurrent chromatography.

Authors:  Yoichiro Ito
Journal:  Chem Eng Process       Date:  2010-07       Impact factor: 4.237

5.  Enantioseparation of (DL)-tryptophan by spiral tube assembly counter-current chromatography and evaluation of mass transfer rate for enantiomers.

Authors:  Shengqiang Tong; Yoichiro Ito; Ying Ma
Journal:  J Chromatogr A       Date:  2014-11-15       Impact factor: 4.759

6.  Triangular Helical Column for Centrifugal Countercurrent Chromatography.

Authors:  Yoichiro Ito; Henry Yu
Journal:  J Liq Chromatogr Relat Technol       Date:  2009       Impact factor: 1.312

7.  Novel design for centrifugal counter-current chromatography: VI. Ellipsoid column.

Authors:  Dongyu Gu; Yi Yang; Xuelei Xin; Haji Akber Aisa; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2015-01-01       Impact factor: 1.312

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.