Literature DB >> 25476690

Enantioseparation of (DL)-tryptophan by spiral tube assembly counter-current chromatography and evaluation of mass transfer rate for enantiomers.

Shengqiang Tong1, Yoichiro Ito2, Ying Ma3.   

Abstract

Spiral tube assembly counter-current chromatography was successfully applied in enantioseparation of dl-tryptophan using bovine serum albumin as chiral selector. An improved biphasic aqueous-aqueous solvent system 12.0% (w/w) polyethyleneglycol 8000-9.0% (w/w) dibasic potassium phosphate-0.1% ammonia-78.9% water was used as the solvent system for counter-current chromatography, in which bovine serum albumin was predominantly distributed in the lower phase of the two-phase aqueous system. The aqueous-aqueous solvent system gave a very high enantioselectivity for d- and l-tryptophan at α=2.605 along with distribution ratio DD=1.200 and DL=0.461. High peak resolution was obtained for enantioseparation of 2.0mg of dl-tryptophan by spiral tube assembly counter-current chromatography under room temperature. It was found that 0.1% ammonia added in the aqueous-aqueous solvent system greatly improved the enantioseparations. An unusual extremely broad peak for l-tryptophan was observed during enantioseparations. In order to give an explanation, mass transfer rates of d- and l-enantiomers through the interface between the two phases were measured. It was found that l-tryptophan showed lower mass transfer rate than d-tryptophan. Further discussions were proposed for possible reasons for mass transfer rate difference between the enantiomers. Published by Elsevier B.V.

Entities:  

Keywords:  Aqueous–aqueous solvent system; Bovine serum albumin; Counter-current chromatography; Enantioseparation; Mass transfer rate; dl-Tryptophan

Mesh:

Substances:

Year:  2014        PMID: 25476690      PMCID: PMC4267995          DOI: 10.1016/j.chroma.2014.11.013

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  13 in total

Review 1.  Enantioseparations in counter-current chromatography and centrifugal partition chromatography.

Authors:  A P Foucault
Journal:  J Chromatogr A       Date:  2001-01-12       Impact factor: 4.759

2.  The specific binding of L-tryptophan to serum albumin.

Authors:  R H McMENAMY; J L ONCLEY
Journal:  J Biol Chem       Date:  1958-12       Impact factor: 5.157

3.  Enantioseparation of phenylsuccinic acid by high speed counter-current chromatography using hydroxypropyl-β-cyclodextrin as chiral selector.

Authors:  Shengqiang Tong; Jizhong Yan; Yi-Xin Guan; Youming Lu
Journal:  J Chromatogr A       Date:  2011-06-17       Impact factor: 4.759

4.  Spiral Tube Assembly for High-Speed Countercurrent Chromatography: Choice of Elution Modes for Four Typical Two-Phase Solvent Systems.

Authors:  Y Ito; R Clary; J Powell; M Knight; T M Finn
Journal:  J Liq Chromatogr Relat Technol       Date:  2008-01-01       Impact factor: 1.312

Review 5.  Spiral countercurrent chromatography.

Authors:  Yoichiro Ito; Martha Knight; Thomas M Finn
Journal:  J Chromatogr Sci       Date:  2013-08       Impact factor: 1.618

6.  Toroidal coil counter-current chromatography study of the mass transfer rate of proteins in aqueous-aqueous polymer phase system.

Authors:  Y Ito; K Matsuda; Y Ma; L Qi
Journal:  J Chromatogr A       Date:  1998-04-10       Impact factor: 4.759

Review 7.  Structure of serum albumin.

Authors:  D C Carter; J X Ho
Journal:  Adv Protein Chem       Date:  1994

8.  Direct chiral resolution in an aqueous two-phase system using the counter-current distribution principle.

Authors:  B Ekberg; B Sellergren; P A Albertsson
Journal:  J Chromatogr       Date:  1985-09-27

9.  A simple chiral high-performance liquid chromatographic method to study the enantiomer-differentiating action of microorganisms. An assay with DL-tryptophan.

Authors:  L Soltés; B Sébille
Journal:  Biomed Chromatogr       Date:  1999-05       Impact factor: 1.902

10.  Liquid chromatographic studies of the effect of phosphate on the binding properties of silica-immobilized bovine serum albumin.

Authors:  W A Tao; R K Gilpin
Journal:  J Chromatogr Sci       Date:  2001-05       Impact factor: 1.618

View more
  3 in total

1.  Comparison in partition efficiency of protein separation between four different tubing modifications in spiral high-speed countercurrent chromatography.

Authors:  Yoichiro Ito; Robert Clary
Journal:  Separations       Date:  2016-10-14

2.  A simple tool for tubing modification to improve spiral high-speed counter-current chromatography for protein purification.

Authors:  Yoichiro Ito; Xiaofeng Ma; Robert Clary
Journal:  Curr Chromatogr       Date:  2016

Review 3.  Chiral Ionic Liquids: Structural Diversity, Properties and Applications in Selected Separation Techniques.

Authors:  Jolanta Flieger; Joanna Feder-Kubis; Małgorzata Tatarczak-Michalewska
Journal:  Int J Mol Sci       Date:  2020-06-15       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.