Cardiopulmonary bypass circuit treated with surface-modifying additives: a clinical evaluation of blood compatibility.

Y J Gu1, P W Boonstra, A A Rijnsburger, J Haan, W van Oeveren.   

Abstract

BACKGROUND: The cardiopulmonary bypass (CPB) circuit induces blood activation and a systemic inflammatory response in cardiac surgical patients. The CPB circuit treated with surface-modifying additive (SMA) has been found to reduce blood activation by in vitro and ex vivo experiments. This study evaluates the surface thrombogenicity and complement activation of SMA circuits during clinical CPB.
METHODS: Twenty patients undergoing coronary artery bypass grafting were randomly divided into two groups. In the SMA group (n = 10), all blood-contacting surfaces in the CPB circuit were treated or coated with SMA, whereas in the control group (n = 10) patients were perfused with an identical circuit without treatment.
RESULTS: During CPB, platelet count and beta-thromboglobulin were found similar in both the SMA and the control groups. Prothrombin activation indicated by fragment F1 + 2 was found less in the SMA group (p < 0.05). After CPB, platelet deposition on the CPB circuit was significantly less (p < 0.05) in the SMA group than in the control group as assessed by the labeled monoclonal antibody against platelet glycoprotein IIIa. Complement activation identified by C3a and terminal complex C5b-9 did not differ between the two groups, but C4a generation was less in the SMA group (p < 0.05). Leukocyte activation identified by elastase and cytokine release indicated by interleukin-8 were found uniformly in both groups. Postoperatively, chest tube drainage, blood transfusion, duration of ventilatory support, as well as the intensive care unit and hospital stay were not significantly different between the two groups.
CONCLUSIONS: These preliminary clinical results suggest that SMA inhibits platelet interaction with the biomaterial surface of the CPB circuit. Complement activation assessed by the terminal complement complex is not influenced by SMA. The clinical benefit of this surface-modifying technique has yet to be assessed in a larger population of patients undergoing cardiac operations.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9594864     DOI: 10.1016/s0003-4975(98)00223-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  In vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass.

Authors:  Angela Ask; David Holt; Lynette Smith
Journal:  J Extra Corpor Technol       Date:  2006-03

2.  Clinical evaluation of poly(2-methoxyethylacrylate) in primary coronary artery bypass grafting.

Authors:  See N Vang; Chad P Brady; Kevin A Christensen; Jack R Isler; Keith R Allen
Journal:  J Extra Corpor Technol       Date:  2005-03

3.  Cardiac surgical patients exposed to heparin-bonded circuits develop less postoperative cerebral dysfunction than patients exposed to non-heparin-bonded circuits.

Authors:  L B Mongero; J R Beck; H E Manspeizer; E J Heyer; K Lee; T A Spanier; C R Smith
Journal:  Perfusion       Date:  2001-03       Impact factor: 1.972

4.  SMART tubing presents an increased risk of disconnection during extracorporeal circulation.

Authors:  Ross Newling; Richard Morris
Journal:  J Extra Corpor Technol       Date:  2005-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.