Literature DB >> 959482

The influence of the counter wall and the counter shape on the spectral energy deposition in small volumes by 60Co gamma-rays and 200 kV x-rays.

R Eickel, J Booz.   

Abstract

The spectral energy deposition in small volumes by 60Co gamma-rays and by 200 kV X-rays was measured with a walled spherical counter, a walled cylindrical counter and a wall-less cylindrical counter. The simulated volumes had dimensions of 0.1--3 mum. By comparing the spectra of the spherical and cylindrical walled counters the influence of the counter shape is derived. The wall effect is discussed by comparing the spectra and the mean lineal energy measured with the walled and the wall-less cylindrical counters. The influence of the counter size and of radiation quality on the energy deposition spectra is also analysed.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 959482     DOI: 10.1007/BF01332175

Source DB:  PubMed          Journal:  Radiat Environ Biophys        ISSN: 0301-634X            Impact factor:   1.925


  4 in total

1.  Distribution of radiation energy in the cell.

Authors:  H H ROSSI
Journal:  Radiology       Date:  1962-04       Impact factor: 11.105

2.  The elimination of the end effects in counters.

Authors:  A L COCKROFT; S C CURRAN
Journal:  Rev Sci Instrum       Date:  1951-01       Impact factor: 1.523

3.  The operation of proportional counters at low pressures for microdosimetry.

Authors:  P J Campion
Journal:  Phys Med Biol       Date:  1971-10       Impact factor: 3.609

4.  An assessment of wall effects in microdosimetric measurements.

Authors:  A M Kellerer
Journal:  Radiat Res       Date:  1971-08       Impact factor: 2.841

  4 in total
  4 in total

1.  Effect of wire eccentricity on the performance of cylindrical proportional counters.

Authors:  E Anachkova; H Roos; E Nekolla; A M Kellerer
Journal:  Radiat Environ Biophys       Date:  1995-11       Impact factor: 1.925

2.  The RBE of 30 kV X-rays for the induction of dicentric chromosomes in human lymphocytes.

Authors:  R P Virsik; D Harder; I Hansmann
Journal:  Radiat Environ Biophys       Date:  1977-07-29       Impact factor: 1.925

3.  Dosimetry of the boron neutron capture reaction for BNCT and BNCEFNT.

Authors:  J Burmeister; C Kota; R L Maughan
Journal:  Strahlenther Onkol       Date:  1999-06       Impact factor: 3.621

4.  Human Health and the Biological Effects of Tritium in Drinking Water: Prudent Policy Through Science - Addressing the ODWAC New Recommendation.

Authors:  S Dingwall; C E Mills; N Phan; K Taylor; D R Boreham
Journal:  Dose Response       Date:  2011-02-22       Impact factor: 2.658

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.