Literature DB >> 9590919

Bond strengths of resin-modified glass ionomers and polyacid-modified resin composites to dentin.

A I Abdalla1, F García-Godoy.   

Abstract

PURPOSE: To measure the shear bond strength of two resin-modified glass ionomers (Vitremer and Fuji II LC) and two polyacid-modified resin composites (Compoglass and Dyract) when applied to dry dentin, dentin supplied with water pressure from the pulp, and after thermocycling.
MATERIALS AND METHODS: Ninety six extracted third molars were used. The root portion was removed just below the cemento-enamel junction and the occlusal enamel was removed from the crown segment. An artificial root portion was made in Plexiglas, cemented to the crown segment and connected to a 36 cm. height water column. The tested materials were applied to the surface of dry dentin, dentin supplied with water pressure from the pulp, and after thermocycling. Shear bond strength was measured for the bonded specimens using an Instron at a crosshead speed of 0.5 mm/minute.
RESULTS: There were no significant differences in bond strengths between Fuji II LC, Compoglass, and Dyract, which were significantly greater than that of Vitremer. The bond strengths of all materials were slightly increased or not affected by the presence of water pressure from the pulp. After thermocycling, the bond strengths of Fuji II LC, Compoglass, and Dyract were not significantly affected whereas those of Vitremer were significantly decreased.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9590919

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  5 in total

1.  Influence of different conditioning methods on the shear bond strength of novel light-curing nano-ionomer restorative to enamel and dentin.

Authors:  Yonca Korkmaz; Emre Ozel; Nuray Attar; Ceren Ozge Bicer
Journal:  Lasers Med Sci       Date:  2009-08-18       Impact factor: 3.161

2.  Microleakage of glass ionomer formulations after erbium:yttrium-aluminium-garnet laser preparation.

Authors:  Katleen I M Delmé; Peter J Deman; Mieke A A De Bruyne; Samir Nammour; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2008-08-21       Impact factor: 3.161

3.  Comparative study to evaluate shear bond strength of RMGIC to composite resin using different adhesive systems.

Authors:  Manoj G Chandak; Navdheeraj Pattanaik; Ayan Das
Journal:  Contemp Clin Dent       Date:  2012-07

4.  Comparative Evaluation of Shear Bond Strength of Bioactive Restorative Material, Zirconia Reinforced Glass Ionomer Cement and Conventional Glass Ionomer Cement to the Dentinal Surface of Primary Molars: an in vitro Study.

Authors:  Komal Nanavati; Farhin Katge; Vamsi Krishna Chimata; Debapriya Pradhan; Aishwarya Kamble; Devendra Patil
Journal:  J Dent (Shiraz)       Date:  2021-12

5.  Bond strength of resin modified glass ionomer cement to primary dentin after cutting with different bur types and dentin conditioning.

Authors:  Rebeca Di Nicoló; Luciana Keiko Shintome; Silvio Issáo Myaki; Marcos Paulo Nagayassu
Journal:  J Appl Oral Sci       Date:  2007-10       Impact factor: 2.698

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.