Literature DB >> 9588930

Correlation of magnetic resonance and oxygen microelectrode measurements of carbogen-induced changes in tumor oxygenation.

H A Al-Hallaq1, J N River, M Zamora, H Oikawa, G S Karczmar.   

Abstract

PURPOSE: The aim of this work was to test the hypothesis that decreases in the linewidth of magnetic resonance (MR) water signals in tumors caused by oxygenating treatments are due to increases in capillary and venous oxygen saturation of hemoglobin, which are tightly coupled to increases in extravascular oxygen tension (pO2). To establish this link, changes measured by MR were compared to changes in tissue pO2 measured directly by oxygen microelectrodes during carbogen (95% O2/5% CO2) inhalation. METHODS AND MATERIALS: Mammary adenocarcinomas (R3230AC) in nine rats were imaged at 4.7 Tesla. T1-weighted (TR = 200 ms, flip angle = 45 degrees) spectroscopic images of the water resonance in a single slice through each tumor were acquired with spectral resolution of 3.9 Hz and bandwidth of +/-1000 Hz. In the same slices in these tumors, microelectrode measurements were made using a non-Clark style oxygen electrode with a 350-micron tip. MR and microelectrode measurements were made during alternating periods of air and carbogen inhalation.
RESULTS: Water resonance linewidth decreased significantly during carbogen-induced hyperoxia. Paired Student's t-test analysis of microelectrode data indicated that pO2 was significantly (p < 0.05) increased as a result of carbogen inhalation. MR and microelectrode data averaged over each tumor demonstrated that decreased MR water signal linewidth is strongly correlated (r = 0.92, p < 0.05) with increased tumor pO2 levels.
CONCLUSION: Although tumor oxygenating agents increase response to radiation in rodent tumors, clinical studies have shown only marginal effects on the radiosensitivity of human tumors. This may be, in part, because the effects of tumor oxygenating treatments are highly heterogeneous both within each tumor and among a population of tumors. The noninvasive, high-resolution MR methods that are validated by the present work could guide the design of new and more effective tumor oxygenating agents and optimize treatments for individual patients.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9588930     DOI: 10.1016/s0360-3016(98)00038-8

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  28 in total

1.  Evaluation of changes in intrarenal oxygenation in rats using multiple gradient-recalled echo (mGRE) sequence.

Authors:  A Priatna; F H Epstein; K Spokes; P V Prasad
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

2.  Response of hepatoma 9618a and normal liver to host carbogen and carbon monoxide breathing.

Authors:  S P Robinson; L M Rodrigues; J R Griffiths; M Stubbs
Journal:  Neoplasia       Date:  1999-12       Impact factor: 5.715

Review 3.  Applications of magnetic resonance in model systems: tumor biology and physiology.

Authors:  R J Gillies; Z M Bhujwalla; J Evelhoch; M Garwood; M Neeman; S P Robinson; C H Sotak; B Van Der Sanden
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

Review 4.  Applications of magnetic resonance in model systems: cancer therapeutics.

Authors:  J L Evelhoch; R J Gillies; G S Karczmar; J A Koutcher; R J Maxwell; O Nalcioglu; N Raghunand; S M Ronen; B D Ross; H M Swartz
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

Review 5.  Causes and effects of heterogeneous perfusion in tumors.

Authors:  R J Gillies; P A Schornack; T W Secomb; N Raghunand
Journal:  Neoplasia       Date:  1999-08       Impact factor: 5.715

6.  Evaluating Estimation Techniques in Medical Imaging Without a Gold Standard: Experimental Validation.

Authors:  John W Hoppin; Matthew A Kupinski; Donald W Wilson; Todd Peterson; Benjamin Gershman; George Kastis; Eric Clarkson; Lars Furenlid; Harrison H Barrett
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2003-02-15

Review 7.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 8.  Imaging tumour hypoxia with oxygen-enhanced MRI and BOLD MRI.

Authors:  James P B O'Connor; Simon P Robinson; John C Waterton
Journal:  Br J Radiol       Date:  2019-01-24       Impact factor: 3.039

9.  Effect of breathing a hyperoxic hypercapnic gas mixture on the oxygenation of meningiomas; preliminary results.

Authors:  Janneke Schuuring; Mark Rijpkema; Hans Bernsen; Pieter Bernsen; Richard van der Maazen; Johannes Kaanders; Albert van der Kogel; Arend Heerschap
Journal:  J Neurooncol       Date:  2002-04       Impact factor: 4.130

10.  Application of an exogenous hyperoxic contrast agent in MR mammography: initial results.

Authors:  Dorothee R Fischer; Jürgen R Reichenbach; Alexander Rauscher; Jan Sedlacik; Werner A Kaiser
Journal:  Eur Radiol       Date:  2004-09-22       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.