Literature DB >> 9584254

Relationship between lens and capsular bag size.

A Vasavada1, R Singh.   

Abstract

PURPOSE: To measure the size of the lens and the empty capsular bag and evaluate the relationship between them.
SETTING: Iladevi Cataract & IOL Research Centre, Ahmedabad, India.
METHODS: In 46 eye-bank eyes, the equatorial diameter of the lens was measured after a corneoscleral button and the iris were removed. Empty capsular bag diameter was measured after extracapsular cataract extraction through an intact capsulorhexis.
RESULTS: Mean lens size was 10.20 mm +/- 0.38 (SD) and mean capsular bag size, 10.38 +/- 0.35 mm. The difference between the size of the lens and that of the empty capsular bag varied from 0 to 0.50 mm (mean 0.20 +/- 0.17 mm). Lenses measuring less than 10.25 mm in diameter showed an increase of 0.25 mm while lenses larger than 10.25 mm showed an increase of 0.09 mm.
CONCLUSION: Lens size was larger in our population than in previous studies. The increase in the empty capsular bag size was related to initial lens size.

Entities:  

Mesh:

Year:  1998        PMID: 9584254     DOI: 10.1016/s0886-3350(98)80300-3

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Clinical outcomes of Ankoris toric intraocular lens implantation using a computer-assisted marker system.

Authors:  Biana Dubinsky-Pertzov; Idan Hecht; Inbal Gazit; Lior Or; Ori Mahler; Shlomo Rotman; Eran Pras; Adi Einan-Lifshitz
Journal:  Int Ophthalmol       Date:  2020-07-27       Impact factor: 2.031

2.  Postoperative astigmatic outcomes based on the haptic axis of intraocular lenses inserted in cataract surgery.

Authors:  In-Tae Kim; Hae-Young Lopilly Park; Hyun-Seung Kim
Journal:  Korean J Ophthalmol       Date:  2011-01-17

3.  Short-term Dynamics after Single- and Three-piece Acrylic Intraocular Lens Implantation: A Swept-source Anterior Segment Optical Coherence Tomography Study.

Authors:  Tatsuhiko Sato; Shunsuke Shibata; Motoaki Yoshida; Ken Hayashi
Journal:  Sci Rep       Date:  2018-07-06       Impact factor: 4.379

4.  Pathology and immunohistochemistry of capsular bag in spontaneously late dislocated capsular bag-intraocular lens complex.

Authors:  Harsha Bhattacharjee; Kasturi Bhattacharjee; Dipankar Das; Manpreet Singh; Piruthivi Sukumar; Diva Kant Misra
Journal:  Indian J Ophthalmol       Date:  2017-10       Impact factor: 1.848

5.  Early-stage clinical outcomes and rotational stability of TECNIS toric intraocular lens implantation in cataract cases with long axial length.

Authors:  Suhong He; Xiang Chen; Xingdi Wu; Yajuan Ma; Xuewen Yu; Wen Xu
Journal:  BMC Ophthalmol       Date:  2020-05-25       Impact factor: 2.209

6.  Geometry of Acrylic, Hydrophobic IOLs and Changes in Haptic-Capsular Bag Relationship According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography.

Authors:  Andreas F Borkenstein; Eva-Maria Borkenstein
Journal:  Ophthalmol Ther       Date:  2022-02-05

7.  Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery.

Authors:  Efstathios Vounotrypidis; Carlo Lackerbauer; Daniel Kook; Martin Dirisamer; Siegfried Priglinger; Wolfgang J Mayer
Journal:  Oman J Ophthalmol       Date:  2018 May-Aug
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.