Literature DB >> 9581059

Radiation patterns of dual concentric conductor microstrip antennas for superficial hyperthermia.

P R Stauffer1, F Rossetto, M Leoncini, G B Gentilli.   

Abstract

The finite difference time domain (FDTD) method has been used to calculate electromagnetic radiation patterns from 915-MHz dual concentric conductor (DCC) microwave antennas that are constructed from thin and flexible printed circuit board (PCB) materials. Radiated field distributions are calculated in homogeneous lossy muscle tissue loads located under variable thickness coupling bolus layers. This effort extends the results of previous investigations to consider more realistic applicator configurations with smaller 2-cm-square apertures and different coupling bolus materials and thicknesses, as well as various spacings of multiple-element arrays. Results are given for practical applicator designs with microstrip feedlines etched on the backside of the PCB antenna array instead of previously tested bulky coaxial-cable feedline connections to each radiating aperture. The results demonstrate that for an optimum coupling bolus thickness of 2.5-5 mm, the thin, flexible, and lightweight DCC antennas produce effective heating to the periphery of each aperture to a depth of approximately 1 cm, and may be combined into arrays for uniform heating of large area superficial tissue regions with the 50% power deposition contour conforming closely to the outer perimeter of the array.

Entities:  

Mesh:

Year:  1998        PMID: 9581059     DOI: 10.1109/10.668751

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  Non-invasive vesicoureteral reflux detection: heating risk studies for a new device.

Authors:  B W Snow; K Arunachalam; V De Luca; P F Maccarini; O Klemetsen; Y Birkelund; T J Pysher; P R Stauffer
Journal:  J Pediatr Urol       Date:  2011-06-12       Impact factor: 1.830

2.  Vesicoureteral reflux in children: a phantom study of microwave heating and radiometric thermometry of pediatric bladder.

Authors:  Yngve Birkelund; Øystein Klemetsen; Svein K Jacobsen; Kavitha Arunachalam; Paolo Maccarini; Paul R Stauffer
Journal:  IEEE Trans Biomed Eng       Date:  2011-09-06       Impact factor: 4.538

Review 3.  Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence.

Authors:  Paul R Stauffer; Paolo Maccarini; Kavitha Arunachalam; Oana Craciunescu; Chris Diederich; Titania Juang; Francesca Rossetto; Jaime Schlorff; Andrew Milligan; Joe Hsu; Penny Sneed; Zeljko Vujaskovic
Journal:  Int J Hyperthermia       Date:  2010       Impact factor: 3.914

4.  DESIGN OF MEDICAL RADIOMETER FRONT-END FOR IMPROVED PERFORMANCE.

Authors:  O Klemetsen; Y Birkelund; S K Jacobsen; P F Maccarini; P R Stauffer
Journal:  Prog Electromagn Res B Pier B       Date:  2011

5.  Microwave Radiometry for Non-Invasive Detection of Vesicoureteral Reflux (VUR) Following Bladder Warming.

Authors:  Paul R Stauffer; Paolo F Maccarini; Kavitha Arunachalam; Valeria De Luca; Sara Salahi; Alina Boico; Oystein Klemetsen; Yngve Birkelund; Svein K Jacobsen; Fernando Bardati; Piero Tognolatti; Brent Snow
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-02-22

Review 6.  Quality assurance guidelines for superficial hyperthermia clinical trials : II. Technical requirements for heating devices.

Authors:  Hana Dobšíček Trefná; Johannes Crezee; Manfred Schmidt; Dietmar Marder; Ulf Lamprecht; Michael Ehmann; Jacek Nadobny; Josefin Hartmann; Nicolleta Lomax; Sultan Abdel-Rahman; Sergio Curto; Akke Bakker; Mark D Hurwitz; Chris J Diederich; Paul R Stauffer; Gerard C Van Rhoon
Journal:  Strahlenther Onkol       Date:  2017-03-01       Impact factor: 3.621

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.