Literature DB >> 9577507

Steady-state and dynamic MR angiography with MS-325: initial experience in humans.

T M Grist1, F R Korosec, D C Peters, S Witte, R C Walovitch, R P Dolan, W E Bridson, E K Yucel, C A Mistretta.   

Abstract

PURPOSE: To evaluate the imaging performance and patient tolerance of a blood-pool contrast agent (MS-325) for magnetic resonance (MR) angiography.
MATERIALS AND METHODS: Imaging of peripheral and carotid vessels was performed in seven healthy volunteers in a phase I clinical trial of the gadolinium chelate MS-325. Each volunteer received an intravenous injection of 0.05 mmol/kg MS-325 over 30 seconds. Dynamic (arterial phase) and steady-state (arterial-venous phase) three-dimensional gradient-echo MR angiograms were acquired during, immediately after, and approximately 50 minutes after injection. Images were ranked (1 [poor] to 5 [excellent]) for overall image quality, and signal-to-noise ratio (S/N) and contrast-to-noise ratio (C/N) were measured by using standard techniques.
RESULTS: All volunteers tolerated the procedure well. The MS-325-enhanced studies demonstrated intense vascular signal. Mean peripheral arterial C/N was 12.9 +/- 4.8 (standard deviation), 78.8 +/- 29.4, 46.1 +/- 10.9, and 41.9 +/- 14.1 for the two-dimensional (2D) time-of-flight (TOF) and the contrast material-enhanced dynamic, early steady-state, and late steady-state images, respectively. Image quality of steady-state postcontrast images was statistically significantly (P < .02) higher than that of 2D TOF images. Image quality of early and late postcontrast images was similar, but a small (10%) decrease in C/N was noted from early to late images.
CONCLUSION: MS-325 provides excellent vascular and selective arterial enhancement during dynamic MR angiography. The long blood residence time also allows acquisition of steady-state images of the arteries and veins with excellent spatial resolution.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9577507     DOI: 10.1148/radiology.207.2.9577507

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  24 in total

1.  Cardiovascular MR angiography.

Authors:  M R Prince; J M Rubin
Journal:  Int J Card Imaging       Date:  1999-04

2.  Contrast enhanced body magnetic resonance angiography.

Authors:  A E Stillman
Journal:  Int J Card Imaging       Date:  1999-04

3.  Magnetic resonance angiography at 0.3 T using MS-325.

Authors:  K M Lahti; R B Lauffer; T Chan; R M Weisskoff
Journal:  MAGMA       Date:  2001-05       Impact factor: 2.310

4.  Multicenter phase-II trial of safety and efficacy of NC100150 for steady-state contrast-enhanced peripheral magnetic resonance angiography.

Authors:  Tim Leiner; Kai Yiu J A M Ho; Vincent B Ho; Georg Bongartz; Willem P T M Mali; Wenche Rasch; Jos M A van Engelshoven
Journal:  Eur Radiol       Date:  2003-01-18       Impact factor: 5.315

5.  Evaluation of a novel macromolecular cascade-polymer contrast medium for dynamic contrast-enhanced MRI monitoring of antiangiogenic bevacizumab therapy in a human melanoma model.

Authors:  Clemens C Cyran; Yanjun Fu; Victor Rogut; Bundit Chaopathomkul; Michael F Wendland; David M Shames; Robert C Brasch
Journal:  Acad Radiol       Date:  2013-10       Impact factor: 3.173

Review 6.  Magnetic resonance angiography in children: technique, indications, and imaging findings.

Authors:  Thomas M Grist; Frank J Thornton
Journal:  Pediatr Radiol       Date:  2004-11-24

7.  Thoracic and abdominal MRA with gadofosveset: influence of injection rate on vessel signal and image quality.

Authors:  Johanna C Nissen; Ulrike I Attenberger; Christian Fink; Olaf Dietrich; Martin Rohrer; Stefan O Schoenberg; Henrik J Michaely
Journal:  Eur Radiol       Date:  2009-03-13       Impact factor: 5.315

Review 8.  Macromolecules, dendrimers, and nanomaterials in magnetic resonance imaging: the interplay between size, function, and pharmacokinetics.

Authors:  Aaron Joseph L Villaraza; Ambika Bumb; Martin W Brechbiel
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

9.  Intravascular contrast agent T1 shortening: fast T1 relaxometry in a carotid volunteer study.

Authors:  Michael Bock; Jessica Schulz; Stefan Ueltzhoeffer; Frederik Giesel; Matthias Voth; Marco Essig
Journal:  MAGMA       Date:  2008-08-29       Impact factor: 2.310

10.  Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.