Literature DB >> 9575248

Evaluation of global and regional left ventricular function using technetium-99m sestamibi ECG-gated single-photon emission tomography.

K T Yang1, H D Chen.   

Abstract

We evaluated a method for the assessment of left ventricular (LV) function with technetium-99m sestamibi ECG-gated single-photon emission tomography (GSPET). GSPET was performed at rest in 21 patients. Images were reconstructed to obtain end-diastolic (ED) and end-systolic (ES) images. Endocardial and epicardial edges of the left ventricle for the ED and ES images were defined using the gradient images and the algorithm developed. LV wall thickness was measured for the mid-ventricular slices of ED and ES images at 10 degrees intervals. The systolic thickening (ST) and the LV ejection fraction [LVEF(GSPECT)] could be determined. These values were compared with the LV ejection fraction (LVEF) estimated using the gated blood pool method. There was a linear correlation between LVEF and ST (r=0.79), and LVEF and LVEF(GSPET) (r=0.87). Histograms of LV thicknesses were generated. Agreement for evaluation of regional wall motion between the method using histograms of LV thicknesses and the gated blood pool study was 92.8% (kappa=0.75). It is concluded that with an appropriate method for LV edge detection, GSPET with 99mTc-labelled perfusion agents is of use for simultaneous evaluation of myocardial perfusion and assessment of LV function.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9575248     DOI: 10.1007/s002590050252

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  5 in total

1.  Comparison between segmental wall motion and wall thickening in patients with coronary artery disease using quantitative gated SPECT software.

Authors:  M B Imran; K Morita; I Adachi; M Konno; N Kubo; T Mochizuki; C Katoh; T Kohya; A Kitabatake; E Tsukamoto; N Tamaki
Journal:  Int J Card Imaging       Date:  2000-08

2.  Clinical validation of technetium-99m MIBI-gated single-photon emission computed tomography (SPECT) for avoiding false positive results in patients with left bundle-branch block: comparison with stress-rest nongated SPECT.

Authors:  Hakan Demir; Güner Erbay; K Metin Kir; Kenan Omurlu; Fatma Berk; Cumali Aktolun
Journal:  Clin Cardiol       Date:  2003-04       Impact factor: 2.882

3.  A realistic 3-D gated cardiac phantom for quality control of gated myocardial perfusion SPET: the Amsterdam gated (AGATE) cardiac phantom.

Authors:  Jacco J N Visser; Ellinor Busemann Sokole; Hein J Verberne; Jan B A Habraken; Huybert J F van de Stadt; Joris E N Jaspers; Morgan Shehata; Paul M Heeman; Berthe L F van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

Review 4.  Gated SPECT in assessment of regional and global left ventricular function: major tool of modern nuclear imaging.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

Review 5.  The expanding role of left ventricular functional assessment using gated myocardial perfusion SPECT: the supporting actor is stealing the scene.

Authors:  Roberto Sciagrà
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-07       Impact factor: 10.057

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.