Literature DB >> 9572505

The dual-ellipse cross vertex path for exact reconstruction of long objects in cone-beam tomography.

F Noo1, R Clack, T A White, T J Roney.   

Abstract

We investigate the way data are used in the algorithm proposed by Kudo and Saito for the exact reconstruction of long objects from axially truncated cone-beam projections. Specifically, we show that the algorithm wastes a large part of the data. To overcome the problem, we propose to use a vertex path consisting of two crossing ellipses, for which we devised a new reconstruction algorithm, called the cross algorithm, which does not waste data and is still suitable to exactly handle axial truncation. Results of reconstruction are presented on simulated data and real data from an experimental scanner.

Entities:  

Mesh:

Year:  1998        PMID: 9572505     DOI: 10.1088/0031-9155/43/4/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Exact Weighted-FBP Algorithm for Three-Orthogonal-Circular Scanning Reconstruction.

Authors:  Hongli Hu; Jianzhou Zhang
Journal:  Sensors (Basel)       Date:  2009-06-12       Impact factor: 3.576

2.  A new method to combine 3D reconstruction volumes for multiple parallel circular cone beam orbits.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Axial Cone-Beam Reconstruction by Weighted BPF/DBPF and Orthogonal Butterfly Filtering.

Authors:  Shaojie Tang; Xiangyang Tang
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-03       Impact factor: 4.538

4.  Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory.

Authors:  Tingliang Zhuang; Joseph Zambelli; Brian Nett; Shuai Leng; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

5.  Task-driven source-detector trajectories in cone-beam computed tomography: I. Theory and methods.

Authors:  J Webster Stayman; Sarah Capostagno; Grace J Gang; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-02

6.  Self-calibration of cone-beam CT geometry using 3D-2D image registration.

Authors:  S Ouadah; J W Stayman; G J Gang; T Ehtiati; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-10       Impact factor: 3.609

7.  A line fiducial method for geometric calibration of cone-beam CT systems with diverse scan trajectories.

Authors:  M W Jacobson; M D Ketcha; S Capostagno; A Martin; A Uneri; J Goerres; T De Silva; S Reaungamornrat; R Han; A Manbachi; J W Stayman; S Vogt; G Kleinszig; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2018-01-16       Impact factor: 3.609

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.