Literature DB >> 9572504

Performance of the Fourier rebinning algorithm for PET with large acceptance angles.

S Matej1, J S Karp, R M Lewitt, A J Becher.   

Abstract

The recently proposed Fourier rebinning (FORE) technique of 3D PET reconstruction is investigated over a wide range of axial acceptance angles. In this study we evaluate the performance of the FORE technique using spatial resolution, contrast and noise figures of merit and compare reconstruction performance of the FORE (followed by multislice 2D reconstruction) to the 3D-RP technique for large-acceptance-angle data (+/-26.25 degrees). Our results show that the FORE technique does not affect the transverse resolution. On the other hand the axial resolution using FORE deteriorates faster, compared with the 3D-RP, at large radii as the acceptance angle increases. Concerning the noise behaviour, we have found that filtering has better ability to suppress the noise in the FORE reconstruction, compared with the 3D-RP reconstruction, especially in the slices near the edge of the axial field of view. Overall, the combination of good performance and fast reconstruction time makes the FORE technique a practical choice for 3D PET applications.

Mesh:

Year:  1998        PMID: 9572504     DOI: 10.1088/0031-9155/43/4/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order method.

Authors:  Kihwan Choi; Jing Wang; Lei Zhu; Tae-Suk Suh; Stephen Boyd; Lei Xing
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Persistent dopamine functions of neurons derived from embryonic stem cells in a rodent model of Parkinson disease.

Authors:  Jose A Rodríguez-Gómez; Jian-Qiang Lu; Iván Velasco; Seth Rivera; Sami S Zoghbi; Jeih-San Liow; John L Musachio; Frederick T Chin; Hiroshi Toyama; Jurgen Seidel; Michael V Green; Panayotis K Thanos; Masanori Ichise; Victor W Pike; Robert B Innis; Ron D G McKay
Journal:  Stem Cells       Date:  2006-12-14       Impact factor: 6.277

3.  Image reconstruction for PET/CT scanners: past achievements and future challenges.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  Imaging Med       Date:  2010-10-01

4.  NEMA NU 2-2007 performance measurements of the Siemens Inveon preclinical small animal PET system.

Authors:  Brad J Kemp; Carrie B Hruska; Aaron R McFarland; Mark W Lenox; Val J Lowe
Journal:  Phys Med Biol       Date:  2009-03-25       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.