Literature DB >> 9571622

Digital radiology using active matrix readout of amorphous selenium: detectors with high voltage protection.

W Zhao1, J Law, D Waechter, Z Huang, J A Rowlands.   

Abstract

A flat-panel x-ray imaging detector is being investigated for digital radiography and fluoroscopy. The detector uses a layer of amorphous selenium (a-Se) to convert x rays to a charge image, which is then electronically read out with a two-dimensional array of thin film transistors (TFTs). In order to sensitize the a-Se layer to x rays, a high voltage (of the order of several thousand volts) is applied to its top surface. The TFTs, which are at the bottom surface of the a-Se layer, are not subjected to any high voltage under normal radiological operational conditions since the pixel potential is < 10 V. However under a fault condition where these two events occur simultaneously: (1) suspended detector scan; and (2) an x-ray exposure more than ten times higher than normal, the voltage on the TFTs could rise to a damaging value. This paper describes a method for protecting the TFTs from high voltage damage under this fault condition. It employs a dual-gate TFT structure, one gate is for scanning control and the other is connected to the pixel electrode for high voltage protection. Before the pixel potential reaches a damaging value, the protection gate turns on the TFT automatically and drains excess charge away from the pixel thus providing a safe pixel saturation potential. In this paper, the characteristic curves of dual-gate TFTs are studied both theoretically and experimentally. The pixel x-ray response for imaging detectors with high voltage protection are predicted, and it is shown that with practical TFT designs the detector can provide a safe pixel saturation potential as well as satisfy the dynamic range required for diagnostic x-ray imaging applications.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9571622     DOI: 10.1118/1.598229

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  The effect of amorphous selenium detector thickness on dual-energy digital breast imaging.

Authors:  Yue-Houng Hu; Wei Zhao
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

Review 2.  Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

Authors:  M M Wronski; J A Rowlands
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

Review 3.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

4.  Comparison of acquisition parameters and breast dose in digital mammography and screen-film mammography in the American College of Radiology Imaging Network digital mammographic imaging screening trial.

Authors:  R Edward Hendrick; Etta D Pisano; Alice Averbukh; Catherine Moran; Eric A Berns; Martin J Yaffe; Benjamin Herman; Suddhasatta Acharyya; Constantine Gatsonis
Journal:  AJR Am J Roentgenol       Date:  2010-02       Impact factor: 3.959

Review 5.  Amorphous and polycrystalline photoconductors for direct conversion flat panel x-ray image sensors.

Authors:  Safa Kasap; Joel B Frey; George Belev; Olivier Tousignant; Habib Mani; Jonathan Greenspan; Luc Laperriere; Oleksandr Bubon; Alla Reznik; Giovanni DeCrescenzo; Karim S Karim; John A Rowlands
Journal:  Sensors (Basel)       Date:  2011-05-09       Impact factor: 3.576