Literature DB >> 9569458

Clinical use of FFP: results of a retrospective process and outcome audit.

H P Jones1, J Jones, J A Napier, S al-Ismail.   

Abstract

An audit has been carried out on the usage of 216 units of fresh frozen plasma (FFP) issued to 41 patients. This involved the systems of FFP issue, the appropriateness of prescription as well as the recorded benefits. Sixty-six per cent of the initial requests for FFP appeared to satisfy criteria for appropriate use. Review of the case notes resulted in some changes to earlier decisions and a slight increase to 73% of those accepted as valid. Only 94% of the FFP issued could be proved to have been given to identified patients and only 88% of case notes showed the reason for treatment. Pre- and post-treatment coagulation results were available for all patients. In 15% of cases, pretreatment results were not significantly abnormal, and consequently no post-treatment improvement found. Coagulation improvement was documented in 78% of cases, and clinical statements on patient progress noted in 40%. In 80% of cases, the patient received other blood products carrying a potential virus risk. Six of the remaining eight patients were treated to stabilize oral anticoagulation. For these patients, virus-inactivated prothrombin concentrates could have been used, resulting in almost the same reduction in virus transmission risk for the group of 41 patients as could be obtained by using virus-inactivated FFP.

Entities:  

Mesh:

Year:  1998        PMID: 9569458     DOI: 10.1046/j.1365-3148.1998.00123.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  4 in total

1.  Prospective audit of the use of fresh-frozen plasma, based on Canadian Medical Association transfusion guidelines.

Authors:  Cynthia Luk; Kathleen M Eckert; Robert M Barr; Ian H Chin-Yee
Journal:  CMAJ       Date:  2002-06-11       Impact factor: 8.262

2.  Tuscan study on the appropriateness of fresh-frozen plasma transfusion (TuSAPlaT).

Authors:  Giancarlo Maria Liumbruno; Maria Laura Sodini; Giuliano Grazzini
Journal:  Blood Transfus       Date:  2007-04       Impact factor: 3.443

3.  An audit of fresh frozen plasma usage in a tertiary trauma care centre in north India.

Authors:  Neha Agarwal; Arulselvi Subramanian; Ravindra Mohan Pandey; Venencia Albert; Sulekha Karjee; Vedanand Arya
Journal:  Indian J Hematol Blood Transfus       Date:  2013-05-15       Impact factor: 0.900

4.  Audit of the clinical use of fresh-frozen plasma in Umbria: study design and results of the pilot phase.

Authors:  Alfonso Iorio; Michela Basileo; Emanuela Marchesini; Gian Paolo Palazzesi; Mario Materazzi; Mauro Marchesi; Antonella Esposito; Lucio Pellegrini; Antonella Germani; Lauretta Rocchetti; Carla Maria Silvani
Journal:  Blood Transfus       Date:  2008-10       Impact factor: 3.443

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.