Literature DB >> 19112736

Audit of the clinical use of fresh-frozen plasma in Umbria: study design and results of the pilot phase.

Alfonso Iorio1, Michela Basileo, Emanuela Marchesini, Gian Paolo Palazzesi, Mario Materazzi, Mauro Marchesi, Antonella Esposito, Lucio Pellegrini, Antonella Germani, Lauretta Rocchetti, Carla Maria Silvani.   

Abstract

BACKGROUND: Fresh-frozen plasma (FFP) is unanimously recognised by international guidelines as the blood component of choice for the management of acute haemorrhage when accompanied by disorders of haemostasis, for disseminated intravascular coagulation in the presence of haemorrhage, for rare bleeding disorders when specific clotting factor concentrates are not available and for thrombotic thrombocytopenic purpura. The literature, however, reports a high percentage of inappropriate requests for FFP. This article presents the results of a pilot study of clinical auditing of the use of FFP in the Region of Umbria (Italy).
METHODS: This study was based on the examination of the requests for FFP made in April 2006 to four Immunotransfusion Services (ITS) in Umbria and of the clinical records of the patients receiving transfusions. The following indicators were identified and evaluated: completeness of the request, appropriateness of the indication and the dose, completeness of the records in the clinical charts, adverse events, in-hospital morbidity and mortality, efficacy of the treatment (evaluated by analysing the changes between pre- and post-transfusion coagulation test results) and, as an indicator of the process, the correspondence between data in the paper request form and in the computerised database. The data were extracted from the ITS databases, from the paper request forms and from the patients' clinical records.
RESULTS: Two hundred and twenty-one requests (615 units of FFP) for 109 patients and 92.8% of the related clinical records were examined. The patients were admitted in medical (22.9%), surgical (51.4%) and critical care units (25.7%). In 50.7% of the cases, the completeness of the data in the individual requests was good (65-80% of the fields filled in). The indication was appropriate in 31.5% of the requests evaluated (56.1% of the total), with no difference related to different requesters. The dosage was appropriate in 62.7% of the requests evaluated (62% of the total). A comparison of pre- and posttransfusion laboratory data showed a significant correction of pathological values (p=0.02) only for the International Normalised Ratio (INR).
CONCLUSIONS: Critical areas that should be targeted by interventions to improve plasma usage are those related to the appropriateness of the indication, the completeness of the data entered in the request forms and the data recorded in the clinical charts.

Entities:  

Mesh:

Year:  2008        PMID: 19112736      PMCID: PMC2626902          DOI: 10.2450/2008.0042-07

Source DB:  PubMed          Journal:  Blood Transfus        ISSN: 1723-2007            Impact factor:   3.443


  23 in total

Review 1.  Transfusion-related acute lung injury.

Authors:  Kathryn E Webert; Morris A Blajchman
Journal:  Transfus Med Rev       Date:  2003-10

2.  Appropriateness of platelet, fresh frozen plasma and cryoprecipitate transfusion in New South Wales public hospitals.

Authors:  William N Schofield; George L Rubin; Mark G Dean
Journal:  Med J Aust       Date:  2003-02-03       Impact factor: 7.738

3.  [Transfusion of fresh coagulated plasma: products, indications. General methods and recommendations].

Authors: 
Journal:  Transfus Clin Biol       Date:  2002 Nov-Dec       Impact factor: 1.406

4.  Improvement in fresh frozen plasma transfusion practice: results of an outcome audit.

Authors:  N Kakkar; R Kaur; J Dhanoa
Journal:  Transfus Med       Date:  2004-06       Impact factor: 2.019

5.  An audit of blood component therapy in a Canadian general teaching hospital.

Authors:  W F Brien; R J Butler; M J Inwood
Journal:  CMAJ       Date:  1989-04-01       Impact factor: 8.262

6.  A critical survey of fresh-frozen plasma use.

Authors:  N Blumberg; J Laczin; A McMican; J Heal; D Arvan
Journal:  Transfusion       Date:  1986 Nov-Dec       Impact factor: 3.157

7.  [Transfusion of fresh frozen plasma (FFP): audit of prescriptions].

Authors:  H Beloeil; M Brosseau; D Benhamou
Journal:  Ann Fr Anesth Reanim       Date:  2001-10

8.  Fresh-frozen plasma and platelet transfusions are associated with development of acute lung injury in critically ill medical patients.

Authors:  Hasrat Khan; Jon Belsher; Murat Yilmaz; Bekele Afessa; Jeffrey L Winters; S Breanndan Moore; Rolf D Hubmayr; Ognjen Gajic
Journal:  Chest       Date:  2007-03-30       Impact factor: 9.410

9.  Evaluation of the appropriateness of blood and blood product transfusion using preset criteria.

Authors:  B Mozes; M Epstein; I Ben-Bassat; B Modan; H Halkin
Journal:  Transfusion       Date:  1989 Jul-Aug       Impact factor: 3.157

10.  Guidelines for the use of fresh-frozen plasma, cryoprecipitate and cryosupernatant.

Authors:  D F O'Shaughnessy; C Atterbury; P Bolton Maggs; M Murphy; D Thomas; S Yates; L M Williamson
Journal:  Br J Haematol       Date:  2004-07       Impact factor: 6.998

View more
  9 in total

Review 1.  Evaluation of clinical appropriateness of blood transfusion.

Authors:  Franco Verlicchi
Journal:  Blood Transfus       Date:  2010-04       Impact factor: 3.443

2.  An audit of fresh frozen plasma usage in a tertiary trauma care centre in north India.

Authors:  Neha Agarwal; Arulselvi Subramanian; Ravindra Mohan Pandey; Venencia Albert; Sulekha Karjee; Vedanand Arya
Journal:  Indian J Hematol Blood Transfus       Date:  2013-05-15       Impact factor: 0.900

3.  Red cell transfusion in orthopaedic surgery: a benchmark study performed combining data from different data sources.

Authors:  Franco Verlicchi; Fausto Desalvo; Gabriele Zanotti; Loretta Morotti; Ivana Tomasini
Journal:  Blood Transfus       Date:  2011-04-12       Impact factor: 3.443

4.  Use of fresh-frozen plasma in 2012 at the Fondazione Ca' Granda Hospital of Milan: assessment of appropriateness using record linkage techniques applied to data routinely recorded in various hospital information systems.

Authors:  Monica Lanzoni; Barbara Olivero; Andrea Artoni; Maurizio Marconi; Elisabetta Raspollini; Silvana Castaldi
Journal:  Blood Transfus       Date:  2017-06-19       Impact factor: 3.443

5.  An audit of fresh frozen plasma usage and effect of fresh frozen plasma on the pre-transfusion international normalized ratio.

Authors:  S A Shinagare; N N Angarkar; S R Desai; M R Naniwadekar
Journal:  Asian J Transfus Sci       Date:  2010-07

6.  The evaluation of the audit of Fresh-Frozen Plasma (FFP) usage in emergency department.

Authors:  Emine Emektar; Seda Dagar; Seref Kerem Corbacioglu; Huseyin Uzunosmanoglu; Mehmet Veysel Oncul; Yunsur Cevik
Journal:  Turk J Emerg Med       Date:  2016-08-20

7.  Transition from fresh frozen plasma to solvent/detergent plasma in the Netherlands: comparing clinical use and transfusion reaction risks.

Authors:  Nicholas H Saadah; Martin R Schipperus; Johanna C Wiersum-Osselton; Marian G van Kraaij; Camila Caram-Deelder; Erik A M Beckers; Anja Leyte; Jan M M Rondeel; Karen M K de Vooght; Floor Weerkamp; Jaap Jan Zwaginga; Johanna G van der Bom
Journal:  Haematologica       Date:  2019-07-04       Impact factor: 9.941

8.  Blood components requests at an orthopedic hospital: a critical survey.

Authors:  Aline Cury Borchardt; Fernanda Azevedo-Silva; Luiz de Melo Amorim Filho
Journal:  Hematol Transfus Cell Ther       Date:  2019-04-23

9.  The quality changes in fresh frozen plasma of the blood donors at high altitude.

Authors:  Zongkui Wang; Hua Liu; Miaomiao Dou; Xi Du; Jijun Hu; Na Su; Ya Wang; Rong Zhang; Changqing Li
Journal:  PLoS One       Date:  2017-04-21       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.