Literature DB >> 9557587

Agreement between a frequency-weighted filter for continuous biomechanical measurements of repetitive wrist flexion against a load and published psychophysical data.

M L Lin1, R G Radwin.   

Abstract

A previous pilot study demonstrated that a force and frequency-weighted filter network could be developed for processing continuous biomechanical measures of repetitive wrist motions and exertions. The current study achieves the objective by modelling subjective discomfort for repetitive wrist flexion using controlled posture, pace and force. A three-level fractional factorial experiment was conducted involving repetitive wrist flexion (2 s/motion, 6 s/motion, 10 s/motion) from a neutral posture to a given angle (10 degrees, 28 degrees, 45 degrees) against a controlled resistance (5 N, 25 N, 50 N) using a Box Behnken design. Ten subjects participated. Discomfort was reported on a 10 cm visual analogue scale. Results of response surface regression analysis revealed that main effects of force, wrist flexion angle, and repetition were all significant (p < 0.05) and that no second-order effects were observed. Linear regression analysis on these factors established a discomfort model on which the filter characteristics were based. The pure error test model revealed no significant lack of fit (p > 0.05). The continuous model was compared and agreed with discrete psychophysical data from other published studies. The model was used for generating parameters for a force and frequency-weighted digital filter that weighs continuous wrist postural signals with corresponding force in proportion to the equal discomfort function as a function of frequency of repetition. These filters will enable integration of large quantities of biomechanical data in field studies.

Mesh:

Year:  1998        PMID: 9557587     DOI: 10.1080/001401398186946

Source DB:  PubMed          Journal:  Ergonomics        ISSN: 0014-0139            Impact factor:   2.778


  4 in total

Review 1.  Pathophysiological tissue changes associated with repetitive movement: a review of the evidence.

Authors:  Ann E Barr; Mary F Barbe
Journal:  Phys Ther       Date:  2002-02

2.  The accuracy of conventional 2D video for quantifying upper limb kinematics in repetitive motion occupational tasks.

Authors:  Chia-Hsiung Chen; David P Azari; Yu Hen Hu; Mary J Lindstrom; Darryl Thelen; Thomas Y Yen; Robert G Radwin
Journal:  Ergonomics       Date:  2015-06-18       Impact factor: 2.778

3.  A hand speed-duty cycle equation for estimating the ACGIH hand activity level rating.

Authors:  Oguz Akkas; David P Azari; Chia-Hsiung Eric Chen; Yu Hen Hu; Sheryl S Ulin; Thomas J Armstrong; David Rempel; Robert G Radwin
Journal:  Ergonomics       Date:  2014-10-24       Impact factor: 2.778

4.  Automated video exposure assessment of repetitive hand activity level for a load transfer task.

Authors:  Chia-Hsiung Chen; Yu Hen Hu; Thomas Y Yen; Robert G Radwin
Journal:  Hum Factors       Date:  2013-04       Impact factor: 2.888

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.