Literature DB >> 9548195

Comparison of dual-isotope acquisition of 201Tl and 99Tcm-tetrofosmin for the detection of ischaemic heart disease and determination of the optimal imaging time of 99Tcm-tetrofosmin.

Y Ito1, T Uehara, K Fukuchi, E Tsujimura, S Hasegawa, T Nishimura.   

Abstract

Comparative studies of thallium-201 (201Tl) and 99Tcm-tetrofosmin for the detection of ischaemic heart disease (IHD) have previously been reported. These 201Tl and 99Tcm-tetrofosmin studies were usually performed separately with different exercise loads at an interval of several days. Here, we used a dual-isotope technique with exercise myocardial SPET (single photon emission tomography) in 17 patients with IHD and 10 patients with normal coronary arteries. The triple-energy window (TEW) method was applied for cross-talk correction. SPET imaging was performed at 10 and 70 min (S1 and S2) after the injection of 99Tcm-tetrofosmin (222 MBq) and 201Tl (74 MBq) at peak exercise to determine the optimal imaging time of 99Tcm-tetrofosmin. The S2 value was obtained 35 min after the subject drank a glass of milk to accelerate hepatobiliary clearance. Twenty-five minutes after S2, 37 MBq of 201Tl were reinjected at rest and SPET imaging (S3) was performed. Immediately after S3, 666 MBq of 99Tcm-tetrofosmin were reinjected and SPET imaging (S4) was performed 50 min later. Representative short and vertical long axis tomograms were divided into 17 segments. Each segment was assessed using a 4-point scoring system. The defect score was defined as the sum of each segmental score. The defect scores for imaging at exercise were 14.3 +/- 11.4 for 201Tl at S1, 11.4 +/- 8 for 99Tcm-tetrofosmin at S1 and 9.7 +/-9.8 for 99Tcm-tetrofosmin at S2 (P < 0.01), respectively. The washout rate of 99Tcm-tetrofosmin for the first hour was 15.5 +/- 7.3% and 11.8 +/- 7.7% (P < 0.01), respectively, for the normal and ischaemic segments. The image quality of 201Tl at S1 was almost equivalent to that of 99Tcm-tetrofosmin at S1/S2. The overall sensitivity and specificity for the detection of ischaemia was 94% and 82% for 201Tl at S1, 89% and 86% for 99Tcm-tetrofosmin at S1, and 88% and 95% for 99Tcm-tetrofosmin at S2, respectively. The overall accuracy was 86%, 88% and 92%, respectively. The myocardial viability score was 7.4 +/- 7.1 for 201Tl at S3 and 5.8 +/- 7.0 for 99Tcm-tetrofosmin at S4 (P < 0.01). The results indicate that the diagnostic accuracy of 99Tcm-tetrofosmin for myocardial ischaemia is almost equivalent to that of 201Tl as assessed by dual SPET imaging, and that the optimal imaging time for 99Tcm-tetrofosmin is within 10-35 min (S1) after exercise.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9548195     DOI: 10.1097/00006231-199802000-00005

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  5 in total

1.  Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera.

Authors:  Simona Ben-Haim; Krzysztof Kacperski; Sharon Hain; Dean Van Gramberg; Brian F Hutton; Kjell Erlandsson; Tali Sharir; Nathaniel Roth; Wendy A Waddington; Daniel S Berman; Peter J Ell
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-04-11       Impact factor: 9.236

2.  Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.

Authors:  P Hannequin; P Weinmann; J Mas; S Vinot
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952

3.  Myocardial imaging with 99mTc-Tetrofosmin: Influence of post-stress acquisition time, regional radiotracer uptake, and wall motion abnormalities on the clinical result.

Authors:  Assuero Giorgetti; Annette Kusch; Mirta Casagranda; Irene D'Aragona Tagliavia; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2009-12-15       Impact factor: 5.952

4.  Technetium-99m pyrophosphate/thallium-201 dual-isotope SPECT imaging predicts reperfusion injury in patients with acute myocardial infarction after reperfusion.

Authors:  Yasushi Akutsu; Kyouichi Kaneko; Yusuke Kodama; Hui-Ling Li; Hideki Nishimura; Yuji Hamazaki; Jumpei Suyama; Akira Shinozuka; Takehiko Gokan; Youichi Kobayashi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-12       Impact factor: 9.236

5.  Tetrofosmin early time gated post-stress single-photon emission computed tomography imaging: feasibility and potential benefits.

Authors:  Laurent Philippe; Bertrand Mérino; Tanguy Blaire; Alban Bailliez; Danielle Casset-Senon; Maurice Levy; Arnaud Halley; Guillaume Divry
Journal:  J Nucl Cardiol       Date:  2010-11-11       Impact factor: 5.952

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.