Literature DB >> 9535491

T wave spectral variance: A new method to determine inhomogeneous repolarization by T wave beat-to-beat variability in patients prone to ventricular arrhythmias.

P Steinbigler1, R Haberl, K Nespithal, A Spiegl, I Schmücking, G Steinbeck.   

Abstract

Inhomogeneous repolarization is considered to be associated with increased risk of ventricular arrhythmias, but exact determination of the end of the T wave is difficult, and a single measurement of the QTc interval may be insufficient for risk stratification. A new algorithm was therefore developed to determine the beat-to-beat variability of the T wave in Holter electrocardiographic recordings. This algorithm, termed T Wave Spectral Variance (TWSV) uses the two-dimensional fast Fourier transform to determine the beat-to-beat variability of the T wave in Hotter ECG recordings. The two-dimensional fast Fourier transform was calculated by use of a data matrix with 1,024 consecutive single beats (first dimension) and a 200-ms segment centered on the T wave (second dimension). The power spectra of the 2D-FFT revealed the frequency content of the T wave in the first dimension and the periodicity of these frequencies in cycles per beat in the second dimension. A TWSV index of periodicity was calculated by dividing total spectral energy by spectral energy at 0 cycles per beat. A TWSV index of 0 means a constant T wave from beat to beat; a TWSV index of 1 means a completely irregular T wave. Of the 200 patients investigated, all of whom had had myocardial infarctions, 50 had documented sustained ventricular tachycardia (VT) (<230 beats/min) (group 1), 50 had ventricular fibrillation (VF) (group 2), and 100 were without VT or VF (group 3); 10 normal subjects were also investigated. The visually determined QTc was 442 +/- 62 ms in group 1, 402 +/- 13 ms in group 2, 411 +/- 26 ms in group 3, and 398 +/- 43 ms in normal subjects (differences not significant). The TWSV index was 0.95 +/- 0.14 in group 1, 0.90 +/- 0.16 in group 2, and 0.64 +/- 0.24 in group 3; it showed a highly constant T wave in normal subjects (0.52 +/- 0.23). Differences between patients with VT and VF as against patients without VT or VF were significant (P < .05), whereas no statistical differences between patients with VT and VF could be found. Thus, TWSV, a new method to assess beat-to-beat variability of the T wave, revealed increased heterogeneity of repolarization in patients prone to both VT and VF after myocardial infarction, whereas a single QTc interval measurement showed no significant differences.

Entities:  

Mesh:

Year:  1998        PMID: 9535491     DOI: 10.1016/s0022-0736(98)80061-7

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  4 in total

1.  Beat-to-beat repolarization variability measured by T wave spectral variance index in chronic infarcted animals.

Authors:  Esteban Raúl Valverde; Ricardo Alberto Quinteiro; Pedro David Arini; Guillermo Claudio Bertrán; Marcelo Oscar Biagetti
Journal:  Ann Noninvasive Electrocardiol       Date:  2002-10       Impact factor: 1.468

2.  Predictive Power of f99 Repolarization Index for the Occurrence of Ventricular Arrhythmias.

Authors:  Corrado Giuliani; Cees A Swenne; Sumche Man; Angela Agostinelli; Sandro Fioretti; Francesco Di Nardo; Laura Burattini
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-11-25       Impact factor: 1.468

3.  T Wave Alternans in high arrhythmic risk patients: analysis in time and frequency domains: a pilot study.

Authors:  Anthony C Hunt
Journal:  BMC Cardiovasc Disord       Date:  2002-03-12       Impact factor: 2.298

4.  Abnormal repolarization in the acute myocardial infarction patients: a frequency-based characterization.

Authors:  Corrado Giuliani; Angela Agostinelli; Sandro Fioretti; Francesco D Nardo; Laura B Burattini
Journal:  Open Biomed Eng J       Date:  2014-07-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.