Literature DB >> 9533828

Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry.

W Drexler1, C K Hitzenberger, A Baumgartner, O Findl, H Sattmann, A F Fercher.   

Abstract

We report on quantitative measurements of group refractive indices and group dispersion in water and in human ocular media such as the cornea, the aqueous humor, the lens, artificial intraocular lenses, as well as a total value averaged over the media along the axial eye length of normal subjects and pseudophakic patients in vivo using dual beam partial coherence interferometry. Different optical thickness values due to the dispersion of the cornea are demonstrated using two spectrally displaced light sources. The displacement can be used to indirectly calculate the group dispersion of the human cornea in the spectral region between 810 nm and 860 nm. If the object under investigation is dispersive, resolution is limited due to a broadening of the detected signals. This broadening increases with group dispersion, i.e., the extent to which the group refractive index of the medium varies with wavelength and thickness of the tissue under investigation as well as with the spectral bandwidth of the light source. Measurements of the group dispersion in the cornea, lens and vitreous of pseudophakic and normal human eyes, show that the cornea and the lens are more dispersive than water-by a factor of about 5 and 2, respectively-in the investigated spectral region. The cornea is approximately threefold more dispersive than the human crystalline lens, the aqueous humor is less dispersive than water and the group dispersion of all ocular components together, averaged over the axial length of normal and pseudophakic eyes, was only slightly higher compared to that of water. Since the highly dispersive cornea and lens together have only a thickness of about one sixth of that of the axial eye length, it seems that their contribution to the group dispersive effect along the whole axial eye length is only small. Copyright 1998 Academic Press Limited.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9533828     DOI: 10.1006/exer.1997.0401

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  17 in total

1.  IOLMaster biometry: refractive results of 100 consecutive cases.

Authors:  H Eleftheriadis
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638

2.  Noninvasive optical coherence tomography monitoring of structure and hydration changes of human corneas in different preservation media.

Authors:  Yicong Wu; Dominic Clarke; Aby Mathew; Ian Nicoud; Xingde Li
Journal:  J Biomed Opt       Date:  2011-02       Impact factor: 3.170

3.  Calculation of ophthalmic viscoelastic device-induced focus shift during femtosecond laser-assisted cataract surgery.

Authors:  Carolina P de Freitas; Florence Cabot; Fabrice Manns; William Culbertson; Sonia H Yoo; Jean-Marie Parel
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-01-27       Impact factor: 4.799

4.  Assessment of eye length changes in accommodation using dynamic extended-depth OCT.

Authors:  Yu-Cherng Chang; Keke Liu; Carolina de Freitas; Alex Pham; Florence Cabot; Siobhan Williams; Ethan Adre; Giovanni Gregori; Marco Ruggeri; Sonia H Yoo; Arthur Ho; Jean-Marie Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2017-04-26       Impact factor: 3.732

5.  Epithelium and Bowman's layer thickness and light scatter in keratoconic cornea evaluated using ultrahigh resolution optical coherence tomography.

Authors:  Rahul Yadav; Ranjini Kottaiyan; Kamran Ahmad; Geunyoung Yoon
Journal:  J Biomed Opt       Date:  2012-11       Impact factor: 3.170

6.  Correlation between optical coherence tomography-derived assessments of lower tear meniscus parameters and clinical features of dry eye disease.

Authors:  Pho Nguyen; David Huang; Yan Li; Srinivas R Sadda; Sylvia Ramos; Rajeev R Pappuru; Samuel C Yiu
Journal:  Cornea       Date:  2012-06       Impact factor: 2.651

7.  Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study.

Authors:  Sheng Zhou; Yan Li; Ake Tzu-Hui Lu; Pengfei Liu; Maolong Tang; Samuel C Yiu; David Huang
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2009 Sep-Oct

8.  In vivo measurement of the average refractive index of the human crystalline lens using optical coherence tomography.

Authors:  Carolina de Freitas; Marco Ruggeri; Fabrice Manns; Arthur Ho; Jean-Marie Parel
Journal:  Opt Lett       Date:  2013-01-15       Impact factor: 3.776

9.  Refractive index measurement of the isolated crystalline lens using optical coherence tomography.

Authors:  Stephen R Uhlhorn; David Borja; Fabrice Manns; Jean-Marie Parel
Journal:  Vision Res       Date:  2008-10-22       Impact factor: 1.886

10.  Reproducibility of a long-range swept-source optical coherence tomography ocular biometry system and comparison with clinical biometers.

Authors:  Ireneusz Grulkowski; Jonathan J Liu; Jason Y Zhang; Benjamin Potsaid; Vijaysekhar Jayaraman; Alex E Cable; Jay S Duker; James G Fujimoto
Journal:  Ophthalmology       Date:  2013-06-04       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.