Literature DB >> 953168

Computer assistance in multiparameter flow microphotometry of mammalian cells.

M Stoehr, U Gebhardt, K Goerttler.   

Abstract

Flow system technology enables the biological and medical experimenter to investigate the distribution spectra of various cellular characteristics separately or in parameter combination on the basis of ultrarapid single cell measurements. A typical rate of recognition is about 1000 to 5000 cells per second and the precision of measurements and their statistical relevance has been previously unobtainable. According to the approach of the multiparameter analysis and high data rate, computer assistance in flow system technology is given primary consideration. In this study three different kinds of software controlled modes in data acquisition are demonstrated: normal acquisition and linear accumulation of single parameters, spectra accumulation of two correlated parameters of each single cell and documentation as linear, two- or three-dimensional distribution pattern, and linear accumulation of two correlated parameters simultaneously with their actual signal-to-signal ratio. A first attempt to analyze distribution spectra was the application of the entropy of the structure routinely used in cybernetics. This function seems to be a measure for determining the degree of synchrony in an appropriate pretreated cell population. A special mathematical strategy has been applied to the linear spectra cellular DNA content, whose advantage is the quantitative extraction of the fractions concerning the various phases of the life cycle cells. The validity of this special curve fitting procedure has been proven on various experimental cell populations.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 953168     DOI: 10.1002/bit.260180804

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  9 in total

1.  Influence of adeno-associated virus on adherence and growth properties of normal cells.

Authors:  U Bantel-Schaal; M Stöhr
Journal:  J Virol       Date:  1992-02       Impact factor: 5.103

2.  Extended application of flow microfluorometry by means of dual laser excitation.

Authors:  M Stöhr; H Eipel; K Goerttler; M Vogt-Schaden
Journal:  Histochemistry       Date:  1977-04-04

3.  Flow microfluorometric monitoring of the interaction of lipid vesicles with cells.

Authors:  D Hock; M Stöhr
Journal:  Histochemistry       Date:  1977-05-20

4.  Low density lipoprotein receptor-dependent prostaglandin synthesis in Swiss 3T3 cells stimulated by platelet-derived growth factor.

Authors:  A J Habenicht; H A Dresel; M Goerig; J A Weber; M Stoehr; J A Glomset; R Ross; G Schettler
Journal:  Proc Natl Acad Sci U S A       Date:  1986-03       Impact factor: 11.205

5.  Clostridium botulinum C2 toxin delays entry into mitosis and activation of p34cdc2 kinase and cdc25-C phosphatase in HeLa cells.

Authors:  H Barth; M Klingler; K Aktories; V Kinzel
Journal:  Infect Immun       Date:  1999-10       Impact factor: 3.441

6.  Combination treatment based on metabolic effects of dinaline.

Authors:  H Schaider; U Haberkorn; E Petru; M R Berger
Journal:  J Cancer Res Clin Oncol       Date:  1995       Impact factor: 4.553

7.  Flow-cytophotometric studies in renal carcinoma.

Authors:  H W Schwabe; H D Adolphs; J Vogel
Journal:  Urol Res       Date:  1983

8.  Lymph node proliferation in patients with urological tumours.

Authors:  H D Adolphs; H W Schwabe
Journal:  Urol Res       Date:  1983

9.  Improved application of impulse cytophotometry for the diagnosis of urinary bladder carcinoma.

Authors:  H W Schwabe; H D Adolphs
Journal:  Urol Res       Date:  1982
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.