BACKGROUND: Computed tomography (CT) has been used to assess patients following endovascular aneurysm repair to determine the need for secondary endoluminal or operative procedures. This prospective study compared CT and duplex imaging to evaluate aneurysm morphology following endoluminal aortic grafting.
METHODS: Twenty patients were evaluated at regular intervals following successful endoluminal aneurysm repair. CT and duplex scanning were compared in their ability to determine aneurysm and aortic diameter, the presence of perigraft extravasation (endoleaks) and technical defects in the endograft.
RESULTS: In 20 patients who were assessed 6 months after operation, duplex imaging identified four endoleaks (two early, two late; one proximal, three distal). In three cases, the aneurysm diameter progressively increased after operation. In patients with a thrombosed aneurysm sac, the aneurysm regressed at a median of 0.40 (range 0.13-0.8) cm per year. The CT findings were similar (median regression 0.43 (range 0-1.0) cm per year), although CT was unable to predict the site of the leak as accurately as duplex imaging. CT demonstrated that the diameter of the juxtarenal aorta increased following endografting.
CONCLUSION: Duplex imaging is a less invasive, less costly alternative to CT in the follow-up of patients after endoluminal aortic surgery. Increase in size of the aneurysm sac following endovascular aneurysm repair strongly suggests the presence of an endoleak.

Entities:  

Mesh:

Year:  1998        PMID: 9529490     DOI: 10.1046/j.1365-2168.1998.00593.x

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  8 in total

1.  Evaluation of the proximal aortic neck enlargement following endovascular repair of abdominal aortic aneurysm: 3-years experience.

Authors:  Vinicio Napoli; Savino G Sardella; Irene Bargellini; Pasquale Petruzzi; Roberto Cioni; Claudio Vignali; Mauro Ferrari; Carlo Bartolozzi
Journal:  Eur Radiol       Date:  2003-04-12       Impact factor: 5.315

2.  [Ultrasound imaging of the abdominal aorta].

Authors:  D-A Clevert; A Horng; M F Reiser
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

3.  [Imaging of endoleaks after endovascular aneurysm repair (EVAR) with contrast-enhanced ultrasound (CEUS)].

Authors:  D-A Clevert; A Horng; R Kopp; K Schick; G Meimarakis; W H Sommer; M Reiser
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

Review 4.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Authors:  Evridiki Karanikola; Ilias Dalainas; Georgios Karaolanis; Georgios Zografos; Konstantinos Filis
Journal:  Int J Angiol       Date:  2014-09

5.  Imaging of aortic abnormalities with contrast-enhanced ultrasound. A pictorial comparison with CT.

Authors:  D-A Clevert; M Stickel; T Johnson; C Glaser; D-A Clevert; H O Steitz; R Kopp; K W Jauch; M Reiser
Journal:  Eur Radiol       Date:  2007-01-12       Impact factor: 5.315

Review 6.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

Review 7.  Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis.

Authors:  Georgios I Karaolanis; Constantine N Antonopoulos; Efstratios Georgakarakos; Georgios D Lianos; Michail Mitsis; Georgios K Glantzounis; Athanasios Giannoukas; George Kouvelos
Journal:  J Clin Med       Date:  2022-06-23       Impact factor: 4.964

8.  Quality of Life After Open Surgical versus Endovascular Repair of Abdominal Aortic Aneurysms.

Authors:  Mustafa Akbulut; Eray Aksoy; İbrahim Kara; Davut Cekmecelioglu; Cengiz Koksal
Journal:  Braz J Cardiovasc Surg       Date:  2018 May-Jun
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.