Literature DB >> 9527202

Reduction of allogeneic blood transfusions after open heart operations by lowering cardiopulmonary bypass prime volume.

O M Shapira1, G S Aldea, P R Treanor, R M Chartrand, K M DeAndrade, H L Lazar, R J Shemin.   

Abstract

BACKGROUND: Despite recent advances in blood conservation techniques, up to 30% to 80% of patients undergoing open heart operations require allogeneic blood transfusions. A prospective, randomized study was performed to test the effect of lowering cardiopulmonary bypass prime volume (as an additional component of an integrated blood conservation strategy) on clinical outcome and allogeneic blood transfusion.
METHODS: One hundred fourteen patients undergoing open heart operations were randomized to either full prime (FP) volume (1,400 mL of Plasmalyte solution) or reduced prime (RP) volume (600 to 800 mL). The reduction of prime volume was achieved by slowly draining the cardiopulmonary bypass circuit into a cell-saving device before the initiation of bypass. Firm transfusion thresholds were observed.
RESULTS: There were no significant differences between the groups with respect to baseline characteristics, body surface area, type and urgency of the procedures, perfusion technique, and hematologic profile. Mortality (FP, 1.7%; RP, 0%; p approximately 1.0) and overall morbidity (FP, 28.1%; RP, 22.8%; p = 0.53) were similar. However, transfusion requirements were significantly lower in the RP group: total donor exposure, 3.8 +/- 10.1 versus 1.0 +/- 2.4 units (p = 0.044); percentage of patients transfused, 54% (n = 31) versus 35% (n = 20) (p = 0.036). Twenty-four-hour chest tube drainage was similar: 455 +/- 223 mL for FP versus 472 +/- 173 mL for RP (p = 0.66). The lowest hematocrit on bypass was significantly higher in the RP group: 29.3% +/- 4% versus 26.3% +/- 5.3% (p = 0.009).
CONCLUSIONS: Lowering cardiopulmonary bypass prime volume resulted in a significant decrease in allogeneic blood product use. Because postoperative 24-hour chest tube drainage was similar in both groups, and hematocrit during bypass was higher in the RP group, the reduction in allogeneic blood transfusions appears to be related to a decrease in prime-induced hemodilution. This technique is effective, simple, and safe. It therefore should be strongly considered for patients undergoing operations using normothermic or near-normothermic cardiopulmonary bypass who are at high risk for allogeneic blood transfusion.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9527202     DOI: 10.1016/s0003-4975(97)01431-8

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  14 in total

1.  Hemoglobin test result variability and cost analysis of eight different analyzers during open heart surgery.

Authors:  Kirti P Patel; Gary W Hay; Mahesh Keitheri Cheteri; David W Holt
Journal:  J Extra Corpor Technol       Date:  2007-03

2.  Assessing the effectiveness of retrograde autologous priming of the cardiopulmonary bypass machine in isolated coronary artery bypass grafts.

Authors:  C Kearsey; J Thekkudan; S Robbins; A Ng; S Lakshmanan; H Luckraz
Journal:  Ann R Coll Surg Engl       Date:  2013-04       Impact factor: 1.891

3.  Early in vivo experience with the pediatric continuous-flow total artificial heart.

Authors:  Jamshid H Karimov; David J Horvath; Nicole Byram; Gengo Sunagawa; Barry D Kuban; Shengqiang Gao; Raymond Dessoffy; Kiyotaka Fukamachi
Journal:  J Heart Lung Transplant       Date:  2018-03-30       Impact factor: 10.247

4.  Recommendations for the transfusion management of patients in the peri-operative period. II. The intra-operative period.

Authors:  Giancarlo Maria Liumbruno; Francesco Bennardello; Angela Lattanzio; Pierluigi Piccoli; Gina Rossetti
Journal:  Blood Transfus       Date:  2011-04       Impact factor: 3.443

Review 5.  Blood Conservation-A Team Sport.

Authors:  Donald S Likosky; Timothy A Dickinson; Theron A Paugh
Journal:  J Extra Corpor Technol       Date:  2016-09

6.  Association of Primary Hemodilution and Retrograde Autologous Priming with Transfusion in Cardiac Surgery: Analysis of the Perfusion Case Database of the Japanese Society of Extra-Corporeal Technology in Medicine.

Authors:  Chihiro Saito; Tetsuya Kamei; Shoji Kubota; Kiyoshi Yoshida; Makoto Hibiya; Shuji Hashimoto
Journal:  J Extra Corpor Technol       Date:  2018-12

7.  Nadir Hematocrit on Bypass and Rates of Acute Kidney Injury: Does Sex Matter?

Authors:  Michelle C Ellis; Theron A Paugh; Timothy A Dickinson; John Fuller; Jeffrey Chores; Gaetano Paone; Michael Heung; Karsten Fliegner; Andrew L Pruitt; Himanshu J Patel; Min Zhang; Richard L Prager; Donald S Likosky
Journal:  Ann Thorac Surg       Date:  2015-08-18       Impact factor: 4.330

8.  The effect of retrograde autologous priming volume on haemodilution and transfusion requirements during cardiac surgery.

Authors:  Korneel Vandewiele; Thierry Bové; Filip M J J De Somer; Daniël Dujardin; Martin Vanackere; Dirk De Smet; Annelies T Moerman; Stefaan Bouchez; Katrien François
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-03-12

9.  Transfusion and bleeding in coronary artery bypass grafting: an on-pump versus off-pump comparison.

Authors:  Kieron C Potger; Darryl McMillan; Joanne Southwell; Terry Connolly; Kate Kingsford Smith; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2007-03

10.  Influence of intraoperative fluid volume on cardiopulmonary bypass hematocrit and blood transfusions in coronary artery bypass surgery.

Authors:  Jeffrey A Campbell; David W Holt; Valerie K Shostrom; Samuel J Durham
Journal:  J Extra Corpor Technol       Date:  2008-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.