Literature DB >> 9525712

Computerized tomography angiography of ruptured cerebral aneurysms: factors affecting time to maximum contrast concentration.

Y Nakajima1, T Yoshimine, H Yoshida, K Sakashita, M Okamoto, M Kishikawa, K Yagi, J Yokota, T Hayakawa.   

Abstract

OBJECT: This study was conducted to assess the diagnostic value of three-dimensional computerized tomography (3-D CT) angiography in demonstrating cerebral aneurysms in 42 consecutive patients presenting with acute subarachnoid hemorrhage (SAH).
METHODS: To obtain the volume data for selective visualization of the cerebral arteries without enhancement of the venous system, the time delay was established between the injection of contrast medium and the start of scanning by using two different methods. The circulation time was calculated with Schad's formula in the first 13 cases, but the results were not satisfactory. In the 29 subsequent cases the time delay was established using a single-level dynamic CT prescan. The dynamic prescan demonstrated the statistical differences in peak time with regard to patient age, SAH grade, and the postresuscitation state after cardiopulmonary arrest. The 3-D CT angiograms were generated from the volume data by using a voxel transmission method. Computerized tomography angiography obtained after optimally adjusted time delay demonstrated the contour of the cerebral arteries in 97% of cases, and aneurysms were detected in 93%. Enhancement of the cavernous sinus and major cortical veins was avoided. Even in patients who suffered cardiopulmonary arrest, images of the major arteries were clearly demonstrated after resuscitation.
CONCLUSIONS: In an emergency situation, CT angiography with a dynamic prescan may be an alternative to magnetic resonance angiography or digital subtraction angiography in the diagnosis of ruptured aneurysms. This modality would also be useful for the precise assessment of small aneurysms, blebs, and aneurysms adjacent to the cavernous sinus.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9525712     DOI: 10.3171/jns.1998.88.4.0663

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  6 in total

1.  Early Experience Studying Cerebral Aneurysms with Rotational and Threedimensional Angiography and Review of CT and MR Angiography Literature.

Authors:  C H Castaño-Duque; J Ruscalleda-Nadal; M de Juan-Delago; E Guardia-Mas; L San Roman-Manzanera; F Bartomeus-Jene; J Molet-Teixido; P Tresserras-Ribo; P Pares-Muñoz; P Clavel Laria
Journal:  Interv Neuroradiol       Date:  2004-10-20       Impact factor: 1.610

2.  The Effect of Contrast Material on Radiation Dose at CT: Part I. Incorporation of Contrast Material Dynamics in Anthropomorphic Phantoms.

Authors:  Pooyan Sahbaee; W Paul Segars; Daniele Marin; Rendon C Nelson; Ehsan Samei
Journal:  Radiology       Date:  2017-01-13       Impact factor: 11.105

3.  The Accuracy and Usefulness of 3D-DSA and 3D-CT Angiography for Cerebral Aneurysms.

Authors:  F Ishida; K Kawaguchi; M Mizuno; T Hoshino; K Murao; W Taki
Journal:  Interv Neuroradiol       Date:  2002-01-10       Impact factor: 1.610

4.  Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Authors:  Sock Keow Tan; Kwan Hoong Ng; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Fadhli Mohamed Sani; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-04

5.  Contrast-to-Noise Ratio Optimization in Coronary Computed Tomography Angiography: Validation in a Swine Model.

Authors:  Logan Hubbard; Shant Malkasian; Yixiao Zhao; Pablo Abbona; Sabee Molloi
Journal:  Acad Radiol       Date:  2018-08-30       Impact factor: 3.173

6.  Angiographic computed tomography and computed tomographic angiography techniques: actual interventional and diagnostic possibilities of their use in patients with cerebral aneurysms.

Authors:  Mario Carvi Y Nievas
Journal:  Neurol Int       Date:  2010-06-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.