Evaluation of the accuracy of a new ultrasonic fetal heart rate monitor.

N H Lauersen, H M Hochberg, M E George.   

Abstract

An indirect Doppler fetal monitoring system has been developed and validated by computer comparison of simultaneous fetal heart rate (FHR) with Doppler and scalp ECG of high-risk patients during labor. The difference in measurement of FHR averaged 0.3 b.p.m., and 93 per cent of the Doppler FHR measures were within 10 b.p.m. of the ECG FHR. If interinstrument difference is discounted, 96 per cent were within 10 b.p.m. All types of decelerations and variability were well approximated. Doppler FHR from the instrument described may be relied upon as valid clinical information and may be obtained from over 90 per cent of labor patients with 93 per cent accuracy.

Entities:  

Mesh:

Year:  1976        PMID: 952309     DOI: 10.1016/0002-9378(76)90819-x

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  6 in total

1.  An open source autocorrelation-based method for fetal heart rate estimation from one-dimensional Doppler ultrasound.

Authors:  Camilo E Valderrama; Lisa Stroux; Nasim Katebi; Elianna Paljug; Rachel Hall-Clifford; Peter Rohloff; Faezeh Marzbanrad; Gari D Clifford
Journal:  Physiol Meas       Date:  2019-02-26       Impact factor: 2.833

2.  Evaluation of fetal wellbeing by antepartum fetal heart monitoring.

Authors:  A M Flynn; J Kelly
Journal:  Br Med J       Date:  1977-04-09

3.  The information content of Doppler ultrasound signals from the fetal heart.

Authors:  S A Shakespeare; J A Crowe; B R Hayes-Gill; K Bhogal; D K James
Journal:  Med Biol Eng Comput       Date:  2001-11       Impact factor: 3.079

4.  A novel technique for fetal heart rate estimation from Doppler ultrasound signal.

Authors:  Janusz Jezewski; Dawid Roj; Janusz Wrobel; Krzysztof Horoba
Journal:  Biomed Eng Online       Date:  2011-10-14       Impact factor: 2.819

5.  A Hybrid EMD-Kurtosis Method for Estimating Fetal Heart Rate from Continuous Doppler Signals.

Authors:  Haitham M Al-Angari; Yoshitaka Kimura; Leontios J Hadjileontiadis; Ahsan H Khandoker
Journal:  Front Physiol       Date:  2017-08-30       Impact factor: 4.566

6.  New Method for Beat-to-Beat Fetal Heart Rate Measurement Using Doppler Ultrasound Signal.

Authors:  Tomasz Kupka; Adam Matonia; Michal Jezewski; Janusz Jezewski; Krzysztof Horoba; Janusz Wrobel; Robert Czabanski; Radek Martinek
Journal:  Sensors (Basel)       Date:  2020-07-22       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.