Literature DB >> 9509350

Goal-directed transesophageal echocardiography performed by intensivists to assess left ventricular function: comparison with pulmonary artery catheterization.

E Benjamin1, K Griffin, A B Leibowitz, A Manasia, J M Oropello, V Geffroy, R DelGiudice, J Hufanda, S Rosen, M Goldman.   

Abstract

OBJECTIVES: Transesophageal echocardiography (TEE) is a valuable procedure for assessing left ventricular (LV) function, but it has not been widely applied in critical care because of the limited number of intensivists who are trained in echocardiography. This prospective study was designed to evaluate the feasibility of training intensivists to perform a goal-directed, limited-scope TEE to assess LV function in critically ill patients using a pediatric monoplane TEE probe. A secondary goal was to compare the usefulness of the TEE data with that of data obtained by a simultaneous pulmonary artery catheter (PAC).
DESIGN: Prospective, blinded.
SETTING: University teaching hospital. PARTICIPANTS: One hundred consecutive, intubated, intensive care unit patients.
INTERVENTIONS: Five surgical intensivists with no previous background in echocardiography were trained under the supervision of two cardiologists to perform limited-scope TEE using a monoplane pediatric probe. One intensivist (A) reviewed the PAC data and recorded a diagnostic impression and therapeutic plan. A second intensivist (B), blinded to the PAC data, then performed TEE to determine cardiac volume, LV wall thickness, and LV global and regional wall motion. Intensivists A and B reviewed the data from both PAC and TEE, and intensivist A then formulated a new diagnosis and therapeutic plan.
MEASUREMENTS AND MAIN RESULTS: Intensivists performed 48 TEE examinations under direct supervision of a cardiologist, and 52 without supervision, but reviewed poststudy. The average duration of TEE was 12 +/- 7 minutes. The intensivists' interpretations of TEE data were deemed correct in 93% of cases for LV wall thickness, 87% for intracardiac volume status, 81% for regional LV wall motion abnormalities, and 77% for global LV function. When the TEE and PAC technologies were compared, it was found that the TEE data disagreed with the PAC evaluation of intracardiac volume in 55% of cases and with the PAC assessment of myocardial function in 39% of cases. The post-PAC therapeutic recommendations were different from the post-TEE therapeutic recommendations in 58% of patients.
CONCLUSIONS: Training intensivists in limited-scope, goal-directed TEE, using a pediatric monoplane probe to evaluate LV function, can be done rapidly and safely, and yield data pertinent to management of critically ill patients even in the early stages of skill acquisition.

Entities:  

Mesh:

Year:  1998        PMID: 9509350     DOI: 10.1016/s1053-0770(98)90048-9

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  21 in total

1.  Bedside echocardiographic evaluation of hemodynamics in sepsis: is a qualitative evaluation sufficient?

Authors:  Antoine Vieillard-Baron; Cyril Charron; Karim Chergui; Olivier Peyrouset; François Jardin
Journal:  Intensive Care Med       Date:  2006-07-20       Impact factor: 17.440

2.  Validation of a skills assessment scoring system for transesophageal echocardiographic monitoring of hemodynamics.

Authors:  Cyril Charron; Gwenaël Prat; Vincent Caille; Guillaume Belliard; Montaine Lefèvre; Philippe Aegerter; Jean-Michel Boles; François Jardin; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2007-08-16       Impact factor: 17.440

3.  Feasibility and influence of hTEE monitoring on postoperative management in cardiac surgery patients.

Authors:  S Treskatsch; F Balzer; F Knebel; M Habicher; J P Braun; M Kastrup; H Grubitzsch; K-D Wernecke; C Spies; M Sander
Journal:  Int J Cardiovasc Imaging       Date:  2015-06-06       Impact factor: 2.357

4.  International expert statement on training standards for critical care ultrasonography.

Authors: 
Journal:  Intensive Care Med       Date:  2011-05-26       Impact factor: 17.440

Review 5.  The ICM research agenda on critical care ultrasonography.

Authors:  P Mayo; R Arntfield; M Balik; P Kory; G Mathis; G Schmidt; M Slama; G Volpicelli; N Xirouchaki; A McLean; A Vieillard-Baron
Journal:  Intensive Care Med       Date:  2017-03-07       Impact factor: 17.440

Review 6.  [Echocardiography during acute hemodynamic instability].

Authors:  C Hainer; M Bernhard; K Scheuren; H Rauch; M A Weigand
Journal:  Anaesthesist       Date:  2006-10       Impact factor: 1.041

Review 7.  Echocardiography in the intensive care unit: from evolution to revolution?

Authors:  Antoine Vieillard-Baron; Michel Slama; Bernard Cholley; Gérard Janvier; Philippe Vignon
Journal:  Intensive Care Med       Date:  2007-11-09       Impact factor: 17.440

8.  Hand-held echocardiography with Doppler capability for the assessment of critically-ill patients: is it reliable?

Authors:  Philippe Vignon; Mickaël B J Frank; Jérôme Lesage; Frédérique Mücke; Bruno François; Sandrine Normand; Michel Bonnivard; Marc Clavel; Hervé Gastinne
Journal:  Intensive Care Med       Date:  2004-01-13       Impact factor: 17.440

9.  A pilot study on safety and clinical utility of a single-use 72-hour indwelling transesophageal echocardiography probe.

Authors:  Antoine Vieillard-Baron; Michel Slama; Paul Mayo; Cyril Charron; Jean-Bernard Amiel; Cédric Esterez; François Leleu; Xavier Repesse; Philippe Vignon
Journal:  Intensive Care Med       Date:  2013-01-04       Impact factor: 17.440

10.  Number of supervised studies required to reach competence in advanced critical care transesophageal echocardiography.

Authors:  Cyril Charron; Philippe Vignon; Gwenaël Prat; Alexandre Tonnelier; Philippe Aegerter; Jean-Michel Boles; Jean-Bernard Amiel; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2013-01-24       Impact factor: 17.440

View more