A new fibre optic sensor for respiratory monitoring.

C Davis1, A Mazzolini, D Murphy.   

Abstract

A new fibre optic plethysmograph has been designed to monitor respiration non invasively. The device incorporates the idea of using thoracic and abdominal belts similar to conventional inductance plethysmography but uses an optical fibre woven into the belts rather than the usual coiled wire. The fibre optic belts incorporate a loop design in the fibre and rely on "macrobending" losses from laser light transmitted down the fibre when the bend radius of the loop changes during respiration. Changes in lung volume are monitored by analysing the relatively large resultant changes in light transmitted through the fibre. The output from the light detector has been interfaced to a computer containing a data acquisition card and the resultant intensity trace is monitored in real time using a virtual instrument created using LabVIEW graphical programming. Preliminary results suggest a highly sensitive system capable of detecting small changes in lung volume using a technique which is not susceptible to electrical noise and which is electrically safe.

Mesh:

Year:  1997        PMID: 9503693

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  6 in total

1.  New sensor based on fibre optics for measurement of heart movement.

Authors:  K Hoeland; A Kloppe; M Hexamer; G Nowack; J Werner
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

Review 2.  Critical review of non-invasive respiratory monitoring in medical care.

Authors:  M Folke; L Cernerud; M Ekström; B Hök
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

3.  Non-invasive respiratory monitoring using long-period fiber grating sensors.

Authors:  M D Petrović; J Petrovic; A Daničić; M Vukčević; B Bojović; Lj Hadžievski; T Allsop; G Lloyd; D J Webb
Journal:  Biomed Opt Express       Date:  2014-03-12       Impact factor: 3.732

4.  The clinical evaluation of the Respi-check mask: a new oxygen mask incorporating a breathing indicator.

Authors:  A Breakell; C Townsend-Rose
Journal:  Emerg Med J       Date:  2001-09       Impact factor: 2.740

5.  Wireless Wearable Ultrasound Sensor to Characterize Respiratory Behavior.

Authors:  Ang Chen; Rachel Diane Rhoades; Andrew Joshua Halton; Jayden Charles Booth; Xinhao Shi; Xiangli Bu; Ning Wu; Junseok Chae
Journal:  Methods Mol Biol       Date:  2022

6.  Tissue artifact removal from respiratory signals based on empirical mode decomposition.

Authors:  Shaopeng Liu; Robert X Gao; Dinesh John; John Staudenmayer; Patty Freedson
Journal:  Ann Biomed Eng       Date:  2013-01-17       Impact factor: 3.934

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.