Literature DB >> 9497812

Roentgen stereophotogrammetric analysis of metal-backed hemispherical cups without attached markers.

E R Valstar1, C W Spoor, R G Nelissen, P M Rozing.   

Abstract

A method for the detection of micromotion of a metal-backed hemispherical acetabular cup is presented and tested. Unlike in conventional roentgen stereophotogrammetric analysis, the cup does not have to be marked with tantalum markers; the micromotion is calculated from the contours of the hemispherical part and the base circle of the cup. In this way, two rotations (tilt and anteversion) and the translations along the three cardinal axes are obtained. In a phantom study, the maximum error in the position of the cup's centre was 0.04 mm. The mean error in the orientation of the cup was 0.41 degree, with a 95% confidence interval of 0.28-0.54 degree. The in vivo accuracy was tested by repeated measurement of 21 radiographs from seven patients. The upper bound of the 95% tolerance interval for the translations along the transversal, longitudinal, and sagittal axes was 0.09, 0.07, and 0.34 mm, respectively: for the rotation, this upper bound was 0.39 degree. These results show that the new method, in which the position and orientation of metal-backed hemispherical cup is calculated from its projected contours, is a simple and accurate alternative to attaching markers to the cup.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9497812     DOI: 10.1002/jor.1100150612

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  6 in total

Review 1.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

2.  Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: an experimental study.

Authors:  Olof Sköldenberg; Magnus Odquist
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

3.  Precision of radiostereometric analysis (RSA) of acetabular cup stability and polyethylene wear improved by adding tantalum beads to the liner.

Authors:  Audrey K Nebergall; Kevin Rader; Henrik Palm; Henrik Malchau; Meridith E Greene
Journal:  Acta Orthop       Date:  2015-05-26       Impact factor: 3.717

4.  The Use of Porous Titanium Coating and the Largest Possible Head Do Not Affect Early Cup Fixation: A 2-Year Report from a Randomized Controlled Trial.

Authors:  Georgios Tsikandylakis; Kristian R L Mortensen; Kirill Gromov; Anders Troelsen; Henrik Malchau; Maziar Mohaddes
Journal:  JB JS Open Access       Date:  2020-12-15

5.  Comparison of early migration patterns between a ceramic and polyethylene liner in uncemented Trabecular Titanium cups: a 2-year randomized controlled trial of 52 hips using radiostereometric analysis.

Authors:  Amanda D Klaassen; Elisabeth A Schäffer; Nienke W Willigenburg; Loes W A H Van Beers; Vanessa A B Scholtes; Victor P M Van der Hulst; Lennard A Koster; Bart L Kaptein; Dirk Jan F Moojen; Rudolf W Poolman
Journal:  Acta Orthop       Date:  2022-04-28       Impact factor: 3.925

6.  Model-based roentgen stereophotogrammetric analysis using elementary geometrical shape models: 10 years results of an uncemented acetabular cup component.

Authors:  Anne Jacobsen; Frank Seehaus; Yutong Hong; Han Cao; Alexander Schuh; Raimund Forst; Stefan Sesselmann
Journal:  BMC Musculoskelet Disord       Date:  2018-09-18       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.