The value of frequent treatment verification films in reducing localization error in the irradiation of complex fields.

J E Marks, A G Haus, H G Sutton, M L Griem.   

Abstract

Using treatment verification film to detect geometric miss or localization error (LE), a follow-up analysis of LE for patients treated with extended mantle fields was made for the period 1973-1974. There were 451 treatment verification films for 19 patients reviewed and 67 errors were detected for an error rate of 15%. This rate represented a continued decrease compared to the previous rate of 35% (330 errors for 902 films) during 1969-73. There was a continued reciprocal increase in number of films per patient per course of treatment which was thought, in part, to account for the improvement in technical precision. Reanalysis of localization error by site within the field showed a decrease in rate of error for the axillae from 1969-73 to 1973-1974 and a relative increase in rate of error for the upper abdominal nodes. The decrease in error rate for the axillae was ascribed to increased attention to leaving adequate margin between pulmonary shield and axilla and the increase in error rate for upper abdominal nodes was ascribed to inadequate margin between shield and spine. The relative increase in errors for the upper abdominal nodes correlated with the physicians who made the original decision about margin between spine and shield. Propagation of LE by site has been noted and can be prevented by monitoring treatment fields with verification film and correcting errors as they are noted.

Entities:  

Mesh:

Year:  1976        PMID: 949695     DOI: 10.1002/1097-0142(197606)37:6<2755::aid-cncr2820370628>3.0.co;2-j

Source DB:  PubMed          Journal:  Cancer        ISSN: 0008-543X            Impact factor:   6.860


  7 in total

1.  Reproducibility of irregular radiation fields for malignant lymphoma.

Authors:  U Mock; K Dieckmann; A M Molitor; U Haverkamp; R Pötter
Journal:  Strahlenther Onkol       Date:  1998-10       Impact factor: 3.621

2.  Development of patient support devices for execution of clinical radiotherapy for cancer patients: A preliminary report.

Authors:  N K Babu; Bakshish Singh; S Namrata; B K Mohanti; R Ravichandran; K E Ghamrawy
Journal:  J Med Phys       Date:  2006-10

3.  Patient-specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy.

Authors:  Michael H Wittmer; Thomas M Pisansky; Jon J Kruse; Michael G Herman
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102

4.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

5.  An Assessment of Dosimetric Characteristics of Inline 2.5 Mega Voltage Unflattened Imaging X-Ray Beam.

Authors:  Tamilarasan Rajamanickam; Sivakumar Muthu; Perumal Murugan; Chinnaiah Dinesan; Chandrasekaran Mekala; Krishnamoorthy Senthilnathan; Narayanasamy Arunai Nambi Raj; Padmanabhan Ramesh Babu
Journal:  Asian Pac J Cancer Prev       Date:  2019-08-01

6.  Verification of setup errors in external beam radiation therapy using electronic portal imaging.

Authors:  K Krishna Murthy; Zakiya Al-Rahbi; S S Sivakumar; C A Davis; R Ravichandran; Kamal El Ghamrawy
Journal:  J Med Phys       Date:  2008-04

7.  Characterization and evaluation of 2.5 MV electronic portal imaging for accurate localization of intra- and extracranial stereotactic radiosurgery.

Authors:  Kwang Hyun Song; Karen Chin Snyder; Jinkoo Kim; Haisen Li; Wen Ning; Robert Rusnac; Paul Jackson; James Gordon; Salim M Siddiqui; Indrin J Chetty
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.