Abstract

PURPOSE: To evaluate the results of implanting convex, iris-fixated, anterior chamber intraocular lenses (IOLs) in phakic eyes to correct high hyperopia.
SETTING: Robert Koch Hospital, Hannover-Gehrden, Germany (Center A), and Dr. Daljit Singh Eye Hospital, Amritsar, India (Center B).
METHOD: Two eyes at Center A and 67 at Center B had implantation of an anterior chamber, convex, iris-fixated IOL. Follow-up of the 2 eyes at Center A was 91 months. Mean follow-up at Center B was 78 months +/- 24 (SD) (range 12 to 120 months).
RESULTS: At Center B, all eyes except two in one patient had clear corneas and no iritis or glaucoma at the last follow-up. The patient with complications (glaucoma and corneal degeneration in both eyes) did not return for follow-up until more than 4 years postoperatively and thus did not have adequate postoperative care.
CONCLUSION: Implantation of a convex iris-claw lens into the anterior chamber of phakic eyes to correct high hyperopia was successful from a refractive aspect. The clinical risks appear tolerable. However, life-long observation by endothelial microscopy is mandatory.

Entities:  

Mesh:

Year:  1998        PMID: 9494899     DOI: 10.1016/s0886-3350(98)80074-6

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  The surgical correction of moderate hypermetropia: the management controversy.

Authors:  C N McGhee; S Ormonde; T Kohnen; M Lawless; A Brahma; I Comaish
Journal:  Br J Ophthalmol       Date:  2002-07       Impact factor: 4.638

Review 2.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

4.  Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant.

Authors:  M Vetrugno; N Cardascia; L Cardia
Journal:  Br J Ophthalmol       Date:  2000-10       Impact factor: 4.638

5.  Phacoemulsification in phakic iris-claw lens with cataract.

Authors:  Sudarshan Khokhar; Manish Mahabir
Journal:  Indian J Ophthalmol       Date:  2018-11       Impact factor: 1.848