Literature DB >> 9479708

Anatomic considerations of the second sacral vertebra and dorsal screw placement.

N A Ebraheim1, J Lu, H Yang, B E Heck, R A Yeasting.   

Abstract

Direct measurements and measurements from images of axial cross-sections on 20 cadaveric sacra that had been scanned on computer were used in this study. The measurements, including parameters from the vertebral body, lateral mass and spinal canal of the second sacral vertebra (S2) were performed. The length of the screw path and the optimal angulation of the screw placement for dorsal sacral internal fixation were also included. The mean values of height, anteroposterior diameter, width and breadth of the S2 were 25.0 mm, 13.5 mm, 29.4 mm and 83.0 mm, respectively. The mean values of the mid-sagittal diameter, maximum transverse diameter and area of the S2 spinal canal were 10.3 mm, 23.1 mm and 162.4 mm2, respectively. The mean transpedicular screw length of the S2 and optimal medial angle were 25.2 mm and 30.0 degrees, respectively. The mean lateral mass screw length of the S2 and optimal lateral angle were 32.8 mm and 22.0 degrees, respectively. The present study provides quantitative anatomic data of the second sacral vertebra. All parameters indicate that, compared with our previous study, S2 is smaller than S1. When S2 lateral mass screw fixation is intended, anchoring the anterior cortex may violate the iliac vessels or lumbosacral trunk; therefore, understanding the unique anatomy of the S2 is imperative.

Entities:  

Mesh:

Year:  1997        PMID: 9479708     DOI: 10.1007/bf01628500

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  4 in total

1.  A radiological evaluation of the morphometry and safety of S1, S2 and S2-ilium screws in the Asian population using three dimensional computed tomography scan: an analysis of 180 pelvis.

Authors:  Mun Keong Kwan; Amit Jeffry; Chris Yin Wei Chan; Lim Beng Saw
Journal:  Surg Radiol Anat       Date:  2011-12-23       Impact factor: 1.246

2.  Neurovascular risks of sacral screws with bicortical purchase: an anatomical study.

Authors:  Ipek Ergur; Omer Akcali; Amac Kiray; Can Kosay; Hamid Tayefi
Journal:  Eur Spine J       Date:  2007-02-14       Impact factor: 3.134

3.  The Universal Clamp hybrid system: a safe technique to correct deformity and restore kyphosis in adolescent idiopathic scoliosis.

Authors:  Guido La Rosa; Giancarlo Giglio; Leonardo Oggiano
Journal:  Eur Spine J       Date:  2013-09-20       Impact factor: 3.134

4.  Sacro-Iliac Joint Sensory Block and Radiofrequency Ablation: Assessment of Bony Landmarks Relevant for Image-Guided Procedures.

Authors:  Trevor J G Robinson; Shannon L Roberts; Robert S Burnham; Eldon Loh; Anne M Agur
Journal:  Biomed Res Int       Date:  2016-09-22       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.