Literature DB >> 9477904

Instrument deterioration with usage: nickel-titanium versus stainless steel.

M L Zuolo1, R E Walton.   

Abstract

Nickel-titanium instruments purportedly resist deformation and loss of sharpness better than do stainless steel instruments but may be more susceptible to breakage. The processes of wear and breakage of nickel-titanium and stainless steel instruments were examined. Sixty files of five types (12 each) and three manufacturers were used. All were used repeatedly in curved canals until failure or for a maximum of 22 minutes. Each instrument was examined with scanning electron microscopy both new (control) and at spaced intervals for evidence of wear and fatigue. All new instruments were of good quality. Stainless steel instrument tended to wear the most rapidly, and next were nickel-titanium rotary instruments; the most resistant to wear were nickel-titanium hand instruments. There were few instrument separations. In general, nickel-titanium (particularly hand) instruments resisted deterioration better than did stainless steel. Nickel-titanium rotary instruments (2 of 12) had the most breakage.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9477904

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  5 in total

1.  Wear resistance of nickel-titanium endodontic files after surface treatment.

Authors:  A P R Alves-Claro; F A E Claro; E T Uzumaki
Journal:  J Mater Sci Mater Med       Date:  2008-05-13       Impact factor: 3.896

2.  Comparative evaluation of surface changes in four Ni-Ti instruments with successive uses - An SEM study.

Authors:  N Subha; Vimal K Sikri
Journal:  J Conserv Dent       Date:  2011-07

3.  A comparative study of root canal shaping using protaper universal and protaper next rotary files in preclinical dental education.

Authors:  Gül Çelik; Feyza Özdemir Kısacık; Emir Faruk Yılmaz; Arife Mersinlioğlu; İhsan Furkan Ertuğrul; Hikmet Orhan
Journal:  PeerJ       Date:  2019-08-19       Impact factor: 2.984

4.  Evaluation of usage-induced degradation of different endodontic file systems.

Authors:  Shekhar Bhatia; Venkateshbabu Nagendrababu; Ove A Peters; Amr Fawzy; Umer Daood
Journal:  Sci Rep       Date:  2021-04-27       Impact factor: 4.379

5.  The Effect of Autoclave Sterilization on Resistance to Cyclic Fatigue of Hero Endodontic File #642 (6%) at Two Artificial Curvature.

Authors:  Masoud Khabiri; Maziar Ebrahimi; Mohammad Reza Saei
Journal:  J Dent (Shiraz)       Date:  2017-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.