Implant diameter and bone density: effect on initial stability and pull-out resistance.

H Kido1, E E Schulz, A Kumar, J Lozada, S Saha.   

Abstract

It is well known that the standard diameter dental implant so often utilized is often inadequate in patients with poor bone quality or quantity, and larger diameter implants have been utilized to overcome this deficiency. The objective of this study was to compare the pull-out resistance of small and large diameter (3.25- and 4.5-mm) dental implants and the relationship of these implants to bone density. Two groups of implants, consisting of 18 implants of each diameter, were placed in the mandibles of five embalmed humans. The bone mineral density of the area surrounding the implant site in the coronal cross section was measured by quantitative computed tomography (QCT). Initial implant stability was tested with a periodontium diagnostic device and pull-out resistance was tested with a mechanical testing system. Results showed the same initial stability for the two implants. The maximum pull-out force required for the large diameter implants was 15% greater than that required for the small diameter implants, although given the small number of samples, this difference was not statistically significant. There were significant positive correlations between the pull-out resistance and the bone density for both the large and small diameter implants (p < 0.05, p < 0.01). We conclude that larger diameter implants appear to have advantages over smaller ones; however, more extensive testing is needed to determine quantitatively the increased load-carrying capacity.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9477851

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  10 in total

1.  Biomechanical properties of orthodontic miniscrews. An in-vitro study.

Authors:  Britta Florvaag; Peter Kneuertz; Frank Lazar; Jürgen Koebke; Joachim E Zöller; Bert Braumann; Robert A Mischkowski
Journal:  J Orofac Orthop       Date:  2010-02-05       Impact factor: 1.938

2.  Predictable aesthetic outcome with immediate placement and early loading of one piece mini implant - A 5 year follow-up case report.

Authors:  C S Anand Mohan; P Harinath; Priyanka K Cholan; D Lokesh Kumar
Journal:  J Int Oral Health       Date:  2014-04-26

3.  A pilot study of mini implants as a treatment option for prosthetic rehabilitation of ridges with sub-optimal bone volume.

Authors:  Anitha Balaji; Jumshad B Mohamed; R Kathiresan
Journal:  J Maxillofac Oral Surg       Date:  2011-02-25

Review 4.  Significance of osteoporosis in craniomaxillofacial surgery: a review of the literature.

Authors:  B Hohlweg-Majert; R Schmelzeisen; B M Pfeiffer; E Schneider
Journal:  Osteoporos Int       Date:  2005-07-16       Impact factor: 4.507

5.  Effects of screw and host factors on insertion torque and pullout strength.

Authors:  Ankit H Shah; Rolf G Behrents; Ki Beom Kim; Hee-Moon Kyung; Peter H Buschang
Journal:  Angle Orthod       Date:  2012-07       Impact factor: 2.079

6.  Survival rate of short, locking taper implants with a plateau design: a 5-year retrospective study.

Authors:  Kemal Özgür Demiralp; Nihat Akbulut; Sebnem Kursun; Didem Argun; Nilsun Bagis; Kaan Orhan
Journal:  Biomed Res Int       Date:  2015-04-16       Impact factor: 3.411

7.  Influence of thread pitch, helix angle, and compactness on micromotion of immediately loaded implants in three types of bone quality: a three-dimensional finite element analysis.

Authors:  Pan Ma; Wei Xiong; Baosheng Tan; Wei Geng; Jiaqiang Liu; Weihong Li; Dehua Li
Journal:  Biomed Res Int       Date:  2014-07-08       Impact factor: 3.411

8.  Simplifying the Treatment of Bone Atrophy in the Posterior Regions: Combination of Zygomatic and Wide-Short Implants-A Case Report with 2 Years of Follow-Up.

Authors:  Fernanda Faot; Geninho Thomé; Amália Machado Bielemann; Caio Hermann; Ana Cláudia Moreira Melo; Luis Eduardo Marques Padovan; Ivete Aparecida de Mattias Sartori
Journal:  Case Rep Dent       Date:  2016-10-27

9.  In-vitro evaluation of the effects of insertion and sterilization procedures on the mechanical and surface characteristics of mini screws.

Authors:  Civan Aved Hergel; Yasemin Bahar Acar; Mustafa Ates; Nazan Kucukkeles
Journal:  Eur Oral Res       Date:  2019-01-01

10.  Three-dimensional finite element analysis of implant-supported crown in fibula bone model.

Authors:  Young-Seok Park; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.