[Measuring intraocular pressure in keratoconus. Effect of the changed biomechanics].

A Böhm1, M Kohlhaas, R C Lerche, B Bischoff, G Richard.   

Abstract

BACKGROUND: Keratoconus is associated with changes in the corneal structure, such as defects of Bowman's layer, a decrease of corneal thickness etc. They result in alterations of some of the biomechanical parameters of the cornea, namely, rigidity and elasticity. The present study was performed to examine how impression tonometry and applanation tonometry for determination of intraocular pressure (IOP) are affected by the changed biomechanical parameters associated with keratoconus. PATIENTS AND METHODS: We examined 20 normal subjects (40 eyes) and 17 keratoconus patients (25 eyes). The corneal thickness was measured by ultrasound pachymetry in the corneal center. In the keratoconus patients, an additional measurement was made at the conus peak. The corneal curvature was determined using the TMS keratoscope. The IOP measurements were made with the Schiötz tonometer (10 g). For comparison, additional IOP measurements in the corneal center and, in the keratoconus group, on the conus peak were made with the applanation tonometer.
RESULTS: The normal subjects had a central corneal thickness of 548 +/- 30 microns, compared to 505 +/- 42 microns in the corneal center and 425 +/- 41 microns on the conus peak in keratoconus patients. The average corneal curvature was 43.3 +/- 1.8 D in the normal subjects and 47.8 +/- 4.1 D in keratoconus patients. Applanation tonometry produced results on 11.33 +/- 1.43 mm Hg in the normal group (corneal center) compared to values of 12.00 +/- 2.55 mm Hg (corneal center) and 7.30 +/- 1.95 mm Hg (conus peak) in the keratoconus cohort. The coefficient of rigidity was 0.0236 +/- 0.0026 microliter-1 in the normal subjects, compared to 0.0173 +/- 0.0050 microliter-1 in the keratoconus patients.
CONCLUSION: The morphological changes associated with keratoconus may cause tonometry errors.

Entities:  

Mesh:

Year:  1997        PMID: 9465707     DOI: 10.1007/s003470050201

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  9 in total

Review 1.  [The risk of glaucoma and corneal thickness].

Authors:  A G Böhm
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

2.  The influence of corneal geometrical and biomechanical properties on tonometry readings in keratoconic eyes.

Authors:  Mustafa Değer Bilgeç; Eray Atalay; Ömer Sözer; Hüseyin Gürsoy; Muzaffer Bilgin; Nilgün Yıldırım
Journal:  Int Ophthalmol       Date:  2019-12-02       Impact factor: 2.031

3.  Stress-Strain Index Map: A New Way to Represent Corneal Material Stiffness.

Authors:  Haixia Zhang; Ashkan Eliasy; Bernardo Lopes; Ahmed Abass; Riccardo Vinciguerra; Paolo Vinciguerra; Renato Ambrósio; Cynthia J Roberts; Ahmed Elsheikh
Journal:  Front Bioeng Biotechnol       Date:  2021-03-11

4.  [Evaluation of dynamic contour tonometry in keratoconus].

Authors:  N Schädle; J D Unterlauft; T Klink; G Geerling
Journal:  Ophthalmologe       Date:  2009-06       Impact factor: 1.059

5.  Which tonometry in eyes with keratoconus?

Authors:  H Altinkaynak; C Kocasarac; H Dundar; N Sayin; N Kara; E Bozkurt; N Duru
Journal:  Eye (Lond)       Date:  2015-12-04       Impact factor: 3.775

6.  Central and peripheral intraocular pressure measured by a rebound tonometer.

Authors:  Tsutomu Yamashita; Atsushi Miki; Yoshiaki Ieki; Junichi Kiryu; Kiyoshi Yaoeda; Motohiro Shirakashi
Journal:  Clin Ophthalmol       Date:  2011-08-10

7.  Detecting IOP Fluctuations in Glaucoma Patients.

Authors:  Brenda Nuyen; Kaweh Mansouri
Journal:  Open Ophthalmol J       Date:  2016-02-29

8.  Intraocular Pressure Measurements Referring to the Corneal Thickness in Keratoconic Eyes After Corneal Crosslinking with Riboflavin and Ultraviolet A.

Authors:  Sanja Sefic Kasumovic; Milka Mavija; Aida Kasumovic; Orhan Lepara; Belkisa Duric-Colic; Emir Cabric; Lejla Muhamedagic; Adisa Sakovic-Racic; Mirko Jankov
Journal:  Med Arch       Date:  2015-10-04

9.  A Critical Assessment of Friedenwald's Technique for Estimating the Coefficient of Rigidity of the Cornea.

Authors:  Larysa Tutchenko; Sudi Patel; Mykhailo Skovron; Olha Horak; Oleksiy Voytsekhivskyy
Journal:  J Ophthalmol       Date:  2022-10-04       Impact factor: 1.974

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.