Literature DB >> 9457349

Stability of different wiring techniques in segmental spinal instrumentation. An experimental study.

K D Heller1, A Prescher, T Schneider, F R Block, R Forst.   

Abstract

The pullout force of sublaminar and transspinous wires for segmental instrumentation which had been inserted into different segments of human cadaver spines were compared. Four different types of wiring were tested: single and double sublaminar wires, button-wires according to Drummond's technique and button-wires with the additional use of two crimps for each spinous process. A total of 50 tests were performed. In all attempts the bone proved to be the limiting factor. None of the 300 fixed wires failed. Typical types of fractures appeared with different wiring techniques. There was no statistically significant difference between the sublaminar wiring techniques tested. However, there were significant differences between sublaminar and transspinous wiring. The transspinous techniques achieved between 30% and 45% of the pull-out strength of sublaminar techniques. The forces decreased with increasing cranialisation. In all techniques the values in the upper segment (D5-D3) were almost half those of the lower segment (L5-L3). The differences of the transspinous techniques increased cranially, in favour of the technique with additional crimps. Thus, the crimps have the strongest effect on weak spinous processes. This study demonstrates that in non-dynamic testing, the stability of the bone and not the type of wiring is the limiting parameter in segmental spinal stabilisation. As the wires are inserted in different areas, the transspinous technique shows significantly lower tension forces in comparison with sublaminar wiring.

Entities:  

Mesh:

Year:  1998        PMID: 9457349     DOI: 10.1007/bf00703452

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

1.  Use of the Universal Clamp for deformity correction and as an adjunct to fusion: preliminary results in scoliosis.

Authors:  Jean-Luc Jouve; Jérôme Sales de Gauzy; Benjamin Blondel; Franck Launay; Franck Accadbled; Gérard Bollini
Journal:  J Child Orthop       Date:  2009-11-28       Impact factor: 1.548

2.  Efficacy of interspinous process lumbar fusion with recombinant human bone morphogenetic protein-2 delivered with a synthetic polymer and β-tricalcium phosphate in a rabbit model.

Authors:  Tomiya Matsumoto; Hiromitsu Toyoda; Sho Dohzono; Hiroyuki Yasuda; Shigeyuki Wakitani; Hiroaki Nakamura; Kunio Takaoka
Journal:  Eur Spine J       Date:  2011-12-28       Impact factor: 3.134

3.  Tadpole system as new lumbar spinal instrumentation.

Authors:  Yuichi Kasai; Tadashi Inaba; Koji Akeda; Atsumasa Uchida
Journal:  J Orthop Surg Res       Date:  2008-09-12       Impact factor: 2.359

  3 in total