Literature DB >> 9457200

Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate--pharmacokinetic analysis and experimental porcine model.

K T Bae1, J P Heiken, J A Brink.   

Abstract

PURPOSE: To investigate the effect of injection rate of contrast medium on aortic and hepatic peak enhancement at computed tomography.
MATERIALS AND METHODS: Early pharmacokinetics of contrast enhancement was analyzed theoretically and simulated with a compartment model. Contrast enhancement curves were generated from the model at different injection rates (0.5-10.0 mL/sec). Time-enhancement curves were measured. The effect of contrast medium injection rate on the time and magnitude of peak enhancement was evaluated and validated empirically in pigs.
RESULTS: Theoretic predictions and experimental results were in good agreement. Time to aortic peak enhancement was the sum of injection duration and bolus transfer time of contrast medium from the injection site to the aorta. Time to hepatic peak enhancement was the sum of injection duration and time to equilibrium. The magnitude of peak enhancement increased with the injection rate, but the increase was different in the aorta and liver.
CONCLUSION: Use of injection rates above 2 mL/sec did not substantially increase hepatic peak enhancement but helped increase the magnitude of arterial enhancement and temporal separation of arterial and venous phases of enhancement for dual-phase spiral CT.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9457200     DOI: 10.1148/radiology.206.2.9457200

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  44 in total

1.  Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography.

Authors:  Isao Yamaguchi; Eiji Kidoya; Masayuki Suzuki; Hirohiko Kimura
Journal:  Radiol Phys Technol       Date:  2010-09-25

2.  Evaluation of a method for improving the detection of hepatocellular carcinoma.

Authors:  Edgar Bendik; Peter B Noël; Daniela Münzel; Alexander A Fingerle; Martin Henninger; Christian Markus; Alain Vlassenbroek; Ernst J Rummeny; Martin Dobritz
Journal:  Eur Radiol       Date:  2013-09-03       Impact factor: 5.315

3.  Preliminary examination to determine the suitable contrast material injection protocol for CT angiography of the pelvis and lower extremities with a multidetector row helical scanner.

Authors:  Minoru Honda; Hideharu Sugimoto; Masao Obuchi; Takashi Narisawa
Journal:  Radiat Med       Date:  2006-05

4.  Effect of varying contrast material iodine concentration and injection technique on the conspicuity of hepatocellular carcinoma during 64-section MDCT of patients with cirrhosis.

Authors:  A Guerrisi; D Marin; R C Nelson; G De Filippis; M Di Martino; H Barnhart; R Masciangelo; I Guerrisi; R Passariello; C Catalano
Journal:  Br J Radiol       Date:  2011-08       Impact factor: 3.039

5.  Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml.

Authors:  F F Behrendt; A H Mahnken; S Keil; M Das; C Hohl; D Bauer; P Seidensticker; E Jost; J E Wildberger; R W Günther; G Mühlenbruch
Journal:  Eur Radiol       Date:  2008-01-29       Impact factor: 5.315

6.  Operation of bolus tracking system for prediction of aortic peak enhancement at multidetector row computed tomography: pharmacokinetic analysis and clinical study.

Authors:  Isao Yamaguchi; Hiroyuki Hayashi; Masayuki Suzuki; Katsuhiro Ichikawa; Eiji Kidoya; Hirohiko Kimura
Journal:  Radiat Med       Date:  2008-07-27

7.  Multislice CT angiography.

Authors:  U Joseph Schoepf; Christoph R Becker; Lars K Hofmann; Marco Das; Thomas Flohr; Bernd M Ohnesorge; Bernhard Baumert; Joshua Rolnick; Jean M Allen; Vassilios Raptopoulos
Journal:  Eur Radiol       Date:  2003-02-26       Impact factor: 5.315

8.  Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose.

Authors:  Chien-Ming Chen; Sung-Yu Chu; Ming-Yi Hsu; Ying-Lan Liao; Hui-Yu Tsai
Journal:  Eur Radiol       Date:  2013-10-02       Impact factor: 5.315

9.  Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT.

Authors:  Kazuo Awai; Shinichi Hori
Journal:  Eur Radiol       Date:  2003-05-08       Impact factor: 5.315

Review 10.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.