Literature DB >> 9456224

Enhanced, simplified glucose sensors: long-term clinical application of wearable artificial endocrine pancreas.

M Shichiri1, M Sakakida, K Nishida, S Shimoda.   

Abstract

At present, 2 major problems should be solved before long-term application of the wearable artificial endocrine pancreas, the development of a reliable and stable glucose monitoring system and the development of a subcutaneous insulin infusion algorithm. With either a miniaturized extracorporeal glucose monitoring system based on microdialysis sampling method or a ferrocene-mediated needle-type glucose sensor covered with highly biocompatible membrane, poly(2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate) (poly[MPC-co-BMA]) membrane, subcutaneous glucose concentrations could be monitored for 7 days without any in vivo calibrations, followed by 14 days with one point calibration. Considering the management and safety of the insulin delivery route, subcutaneous insulin infusion is obligatory. With the subcutaneous insulin infusion algorithm using a short acting insulin analogue (Insulin Lispro), near physiological glycemic control could be established in diabetic patients without showing any delayed hyperinsulinemia or hypoglycemia. The wearable artificial endocrine pancreas is now recognized as an excellent therapeutic tool for regulating blood glucose excursions physiologically in ambulatory diabetic patients on a long-term basis.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9456224     DOI: 10.1046/j.1525-1594.1998.06043.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  5 in total

1.  Peculiarities of the continuous glucose monitoring data stream and their impact on developing closed-loop control technology.

Authors:  Boris Kovatchev; William Clarke
Journal:  J Diabetes Sci Technol       Date:  2008-01

Review 2.  Stimuli sensitive polymers and self regulated drug delivery systems: a very partial review.

Authors:  Ronald A Siegel
Journal:  J Control Release       Date:  2014-06-28       Impact factor: 9.776

3.  The artificial pancreas: how sweet engineering will solve bitter problems.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2007-01

Review 4.  Artificial pancreas: past, present, future.

Authors:  Claudio Cobelli; Eric Renard; Boris Kovatchev
Journal:  Diabetes       Date:  2011-11       Impact factor: 9.461

5.  Acute response in vivo of a fiber-optic sensor for continuous glucose monitoring from canine studies on point accuracy.

Authors:  Kuo-Chih Liao; Shih-Chieh Chang; Cheng-Yang Chiu; Yu-Hsiang Chou
Journal:  Sensors (Basel)       Date:  2010-08-20       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.