Calibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies.

A W Buis1, P Convery.   

Abstract

Force sensing resistors (FSR) have been used to measure dynamic pressures at the interface between appliance and patient. Inaccuracies using FSRs have been reported. This paper summarises both the calibration problems encountered and the techniques adopted to minimise inaccuracies. It is considered that, by calibrating the transducers attached to the socket, and by adopting a strict test protocol, FSRs may provide a guide to the dynamic pressure distribution applied to the trans-tibial stump during gait.

Entities:  

Mesh:

Year:  1997        PMID: 9453089     DOI: 10.3109/03093649709164552

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  9 in total

1.  The effect of biomechanical variables on force sensitive resistor error: Implications for calibration and improved accuracy.

Authors:  Jonathon S Schofield; Katherine R Evans; Jacqueline S Hebert; Paul D Marasco; Jason P Carey
Journal:  J Biomech       Date:  2016-02-09       Impact factor: 2.712

2.  Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics.

Authors:  Eric Swanson; Ethan Weathersby; John Cagle; Joan E Sanders
Journal:  J Biomech Eng       Date:  2019-04-24       Impact factor: 2.097

3.  Investigation of Regression Methods for Reduction of Errors Caused by Bending of FSR-Based Pressure Sensing Systems Used for Prosthetic Applications.

Authors:  Chakaveh Ahmadizadeh; Carlo Menon
Journal:  Sensors (Basel)       Date:  2019-12-13       Impact factor: 3.576

4.  Effect of Contacting Surface on the Performance of Thin-Film Force and Pressure Sensors.

Authors:  Ka Po Maggie Tang; Kit Lun Yick; Pui Ling Li; Joanne Yip; King Hei Or; Kam Hong Chau
Journal:  Sensors (Basel)       Date:  2020-11-30       Impact factor: 3.576

5.  The capability of fiber Bragg grating sensors to measure amputees' trans-tibial stump/socket interface pressures.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Arezoo Eshraghi; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2013-08-12       Impact factor: 3.576

Review 6.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13

7.  Development of an air pneumatic suspension system for transtibial prostheses.

Authors:  Gholamhossein Pirouzi; Noor Azuan Abu Osman; Azim Ataollahi Oshkour; Sadeeq Ali; Hossein Gholizadeh; Wan A B Wan Abas
Journal:  Sensors (Basel)       Date:  2014-09-09       Impact factor: 3.576

Review 8.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

9.  Characterization of interfacial socket pressure in transhumeral prostheses: A case series.

Authors:  Jonathon S Schofield; Katherine R Schoepp; Heather E Williams; Jason P Carey; Paul D Marasco; Jacqueline S Hebert
Journal:  PLoS One       Date:  2017-06-02       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.