Literature DB >> 9448765

Staging of invasive cervical carcinoma and of pelvic lymph nodes by high resolution MRI with a phased-array coil in comparison with pathological findings.

H Hawighorst1, S O Schoenberg, P G Knapstein, M V Knopp, U Schaeffer, M Essig, G van Kaick.   

Abstract

PURPOSE: Our goal was to stage invasive cervical carcinoma (pT1b-pT4a) and pelvic lymph nodes by high resolution MRI with a circularly polarized (cp) phased-array coil in correlation with the whole-mount specimen and the histopathological findings.
METHOD: Thirty-three patients (20-68 years old; mean age 55 years) with biopsy-proven primary cancer of the cervix were prospectively examined on a 1.5 T scanner by using a cp body phased-array coil. The MR protocol consisted of high resolution T2-weighted turbo-SE (TSE) and pre- and postcontrast T1-weighted SE (SE) sequences. Slice thickness was 5-7 mm with a pixel size of 0.3-0.4 mm2. All MRI findings were matched to the whole-mount specimens and the histopathological findings.
RESULTS: Pathological stages evaluated were pT1b (n = 5), pT2b (n = 16), and pT4a (n = 12). The overall accuracy rates for tumor staging were 79% for high resolution T2-weighted TSE and 76% for postcontrast T1-weighted SE images. The accuracy for high resolution T2-weighted TSE images in determining parametrial infiltration, pelvic side wall, and bladder and rectal wall infiltration was 84, 87, and 87%, respectively. In prospective analysis of the 1.0 cm criterion for diagnosis of a positive pelvic lymph node, MRI had a 72% accuracy, a 68% sensitivity, and a 78% specificity.
CONCLUSION: High resolution MRI with a cp body phased-array coil provides excellent and robust high resolution images in patients with invasive cervical carcinoma. However, accuracy, specificity, and sensitivity for staging invasive cervical carcinoma and pelvic lymph nodes with correlation to whole-mount specimens and histopathological findings did not improve compared with the results in the literature using a body coil with thicker slices and a lower spatial resolution.

Entities:  

Mesh:

Year:  1998        PMID: 9448765     DOI: 10.1097/00004728-199801000-00013

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  12 in total

1.  Cervical cancer: MR imaging findings before, during, and after radiation therapy.

Authors:  Gulgun Engin
Journal:  Eur Radiol       Date:  2005-06-14       Impact factor: 5.315

Review 2.  Diagnostic performance of diffusion-weighted MRI for detection of pelvic metastatic lymph nodes in patients with cervical cancer: a systematic review and meta-analysis.

Authors:  G Shen; H Zhou; Z Jia; H Deng
Journal:  Br J Radiol       Date:  2015-05-29       Impact factor: 3.039

3.  MRI Evaluation of Local Extent of Carcinoma Cervix - Is Post Contrast Imaging Needed in Every Case?

Authors:  Joish Upendra Kumar; Ramireddy Harikiran Reddy; Pallavi Sinha; Niveditha Kodali; Vivek Sreekanth
Journal:  J Clin Diagn Res       Date:  2017-05-01

4.  Comparison of DWI and PET/CT in evaluation of lymph node metastasis in uterine cancer.

Authors:  Kazuhiro Kitajima; Erena Yamasaki; Yasushi Kaji; Koji Murakami; Kazuro Sugimura
Journal:  World J Radiol       Date:  2012-05-28

5.  Indications for endoscopy according to the revised FIGO staging for cervical cancer after MRI and CT scanning.

Authors:  Bae Kwon Jeong; Seung Jae Huh; Doo Ho Choi; Won Park; Dongryul Oh; Taegyu Kim; Hye Bin Lee
Journal:  J Gynecol Oncol       Date:  2012-04-03       Impact factor: 4.401

Review 6.  Clinical examination versus magnetic resonance imaging in the pretreatment staging of cervical carcinoma: systematic review and meta-analysis.

Authors:  Maarten G Thomeer; Cees Gerestein; Sandra Spronk; Helena C van Doorn; Els van der Ham; Myriam G Hunink
Journal:  Eur Radiol       Date:  2013-03-01       Impact factor: 5.315

7.  Accuracy of integrated FDG-PET/contrast-enhanced CT in detecting pelvic and paraaortic lymph node metastasis in patients with uterine cancer.

Authors:  Kazuhiro Kitajima; Koji Murakami; Erena Yamasaki; Yasushi Kaji; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2009-01-29       Impact factor: 5.315

8.  Comparison of retrospective PET and MRI-DWI (PET/MRI-DWI) image fusion with PET/CT and MRI-DWI in detection of cervical and endometrial cancer lymph node metastases.

Authors:  Alessandro Stecco; Francesco Buemi; Alessia Cassarà; Roberta Matheoud; Gian Mauro Sacchetti; Alberto Arnulfo; Marco Brambilla; Alessandro Carriero
Journal:  Radiol Med       Date:  2016-03-31       Impact factor: 3.469

Review 9.  PET/MRI in Oncological Imaging: State of the Art.

Authors:  Usman Bashir; Andrew Mallia; James Stirling; John Joemon; Jane MacKewn; Geoff Charles-Edwards; Vicky Goh; Gary J Cook
Journal:  Diagnostics (Basel)       Date:  2015-07-21

10.  MR staging in carcinoma of the endometrium and carcinoma of the cervix.

Authors:  M V Pakkal; V Rudralingam; W G McCluggage; B E Kelly
Journal:  Ulster Med J       Date:  2004-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.