Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis.

L A Kearse1, C Rosow, A Zaslavsky, P Connors, M Dershwitz, W Denman.   

Abstract

BACKGROUND: The bispectral index (BIS) measures changes in the interfrequency coupling of the electroencephalogram (EEG). The purposes of this study were (1) to determine whether BIS correlates with responses to command during sedation and hypnosis induced by propofol or propofol and nitrous oxide, and (2) to compare BIS to targeted and measured concentrations of propofol in predicting participants' responses to commands.
METHODS: Twenty volunteers (15 men and 5 women, aged 22-50 yr) were given propofol by computer-controlled infusion, and EEG was recorded for off-line analysis of BIS. Responses to randomly ordered verbal commands or voice plus touch were measured with two categorical scales (CS1 and CS2, respectively). All subjects received a propofol infusion targeted to achieve effect site concentrations of 1, 2, 4, 2, 1, and 0 microg/ml. Ten participants had repeated infusion, whereas 10 others breathed 30% nitrous oxide and oxygen and received a propofol infusion targeted for 0.5, 1, 2, 4, 2, 1, 0.5, and 0 microg/ml. Five minutes after each targeted concentration had been reached, CS1, CS2, and arterial propofol concentration were determined. The area under the receiver operating characteristic curve was used to compare the accuracy of (1) BIS, (2) targeted propofol concentration, (3) measured concentration, and (4) treatment history as predictors of response.
RESULTS: Bispectral index was a strong predictor of CS1 and CS2 (P < 0.0001) and significantly more accurate than targeted or measured propofol concentrations (P < 0.0003 and P < 0.003, respectively). It also provided additional predictive power when combined with treatment history (P < 0.02). Nitrous oxide slightly decreased the probability of response at a given value of BIS (P < 0.05), but accuracy was unaffected.
CONCLUSIONS: Bispectral index accurately predicts response to verbal commands during sedation and hypnosis with propofol or propofol plus nitrous oxide. Accuracy is maintained in situations likely to be encountered during clinical use: when propofol concentrations are increasing or decreasing and when repeated measurements are made over time.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9447852     DOI: 10.1097/00000542-199801000-00007

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  34 in total

1.  Predicting movement during anaesthesia by complexity analysis of electroencephalograms.

Authors:  X S Zhang; R J Roy
Journal:  Med Biol Eng Comput       Date:  1999-05       Impact factor: 2.602

2.  Bispectral index evaluation of the sedative effect of acupuncture in healthy volunteers.

Authors:  Luca Cabrini; Luigi Gioia; Marco Gemma; Valeria Cedrati; Martina Crivellari
Journal:  J Clin Monit Comput       Date:  2006-09-19       Impact factor: 2.502

3.  Comparison of electrophysiologic monitors with clinical assessment of level of sedation.

Authors:  Christopher J Chisholm; Joseph Zurica; Dmitry Mironov; Robert R Sciacca; Eugene Ornstein; Eric J Heyer
Journal:  Mayo Clin Proc       Date:  2006-01       Impact factor: 7.616

4.  Comparison of the EEG-based SNAP index and the Bispectral (BIS) index during sevoflurane-nitrous oxide anaesthesia.

Authors:  P Ruiz-Gimeno; M Soro; A Pérez-Solaz; M Carrau; F J Belda; J L Jover; G Aguilar
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

5.  Dopamine-dependent non-linear correlation between subthalamic rhythms in Parkinson's disease.

Authors:  S Marceglia; G Foffani; A M Bianchi; G Baselli; F Tamma; M Egidi; A Priori
Journal:  J Physiol       Date:  2006-01-12       Impact factor: 5.182

6.  Delirium: a cognitive cost of the comfort of procedural sedation in elderly patients?

Authors:  Gregory Crosby; Deborah J Culley; Edward R Marcantonio
Journal:  Mayo Clin Proc       Date:  2010-01       Impact factor: 7.616

7.  A novel system for automated propofol sedation: hybrid sedation system (HSS).

Authors:  Cedrick Zaouter; Riccardo Taddei; Mohamad Wehbe; Erik Arbeid; Shantale Cyr; Francesco Giunta; Thomas M Hemmerling
Journal:  J Clin Monit Comput       Date:  2016-03-12       Impact factor: 2.502

8.  Electroencephalogram signatures of loss and recovery of consciousness from propofol.

Authors:  Patrick L Purdon; Eric T Pierce; Eran A Mukamel; Michael J Prerau; John L Walsh; Kin Foon K Wong; Andres F Salazar-Gomez; Priscilla G Harrell; Aaron L Sampson; Aylin Cimenser; ShiNung Ching; Nancy J Kopell; Casie Tavares-Stoeckel; Kathleen Habeeb; Rebecca Merhar; Emery N Brown
Journal:  Proc Natl Acad Sci U S A       Date:  2013-03-04       Impact factor: 11.205

9.  Bispectral index monitor: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2004-06-01

10.  Protocol for the "Michigan Awareness Control Study": A prospective, randomized, controlled trial comparing electronic alerts based on bispectral index monitoring or minimum alveolar concentration for the prevention of intraoperative awareness.

Authors:  George A Mashour; Kevin K Tremper; Michael S Avidan
Journal:  BMC Anesthesiol       Date:  2009-11-05       Impact factor: 2.217