Effects of flow triggering on breathing effort during partial ventilatory support.

P Aslanian1, S El Atrous, D Isabey, E Valente, D Corsi, A Harf, F Lemaire, L Brochard.   

Abstract

The effects of flow triggering (FT) as compared with pressure triggering (PT) on breathing effort have been the focus of several studies, and discrepant results have been reported. In the initial part of our study, a lung model was used to quantify triggering effort (airway pressure-time product, PTPaw) for a range of sensitivity settings in nine new-generation ventilators. A ventilator providing both FT and PT was then used to compare these systems during pressure-support (PSV) and volume-targeted assist-control ventilation (ACV) in eight ventilator-dependent patients, using sensitivity settings (2 L/min for FT and -2 cm H2O for PT) that had proven significantly different in the initial bench study. Indexes of effort included the esophageal and transdiaphragmatic pressure-time products and inspiratory work of breathing per minute (PTPes/min, PTPdi/min, and Wi/min, respectively). The experimental study revealed significant differences between ventilators in PTPaw at commonly used settings. In two of three ventilators featuring both systems, PTPaw was significantly lower with FT than PT (p < 0.001). In the clinical study, FT as compared with PT, was associated with reductions in all indexes of breathing effort during PSV: 16 +/- 6% (p < 0.001), 13 +/- 10% (p < 0.01), and 14 +/- 12% (p < 0.05) for PTPdi/min, PTPes/min, and Wi/min, respectively. By contrast, no differences were found when FT was used during ACV. Although FT reduced triggering effort in both modes (p < 0.001), the effects observed during the post-trigger phase differed, and explained the discrepant results between the two modes. We conclude that FT more effectively reduces breathing effort when used in conjunction with a pressure-targeted mode than with a volume-targeted mode, especially when flow delivery is close to or below demand.

Entities:  

Mesh:

Year:  1998        PMID: 9445291     DOI: 10.1164/ajrccm.157.1.96-12052

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  25 in total

Review 1.  International Consensus Conferences in Intensive Care Medicine: non-invasive positive pressure ventilation in acute respiratory failure. Organised jointly by the American Thoracic Society, the European Respiratory Society, the European Society of Intensive Care Medicine, and the Société de Réanimation de Langue Française, and approved by the ATS Board of Directors, December 2000.

Authors:  T W Evans
Journal:  Intensive Care Med       Date:  2001-01       Impact factor: 17.440

2.  Bench studies evaluating devices for non-invasive ventilation: critical analysis and future perspectives.

Authors:  Carlo Olivieri; Roberta Costa; Giorgio Conti; Paolo Navalesi
Journal:  Intensive Care Med       Date:  2011-11-29       Impact factor: 17.440

Review 3.  Work of breathing.

Authors:  Belen Cabello; Jordi Mancebo
Journal:  Intensive Care Med       Date:  2006-07-13       Impact factor: 17.440

4.  Pseudo-double-triggering.

Authors:  Chang-Wen Chen; Wei-Chieh Lin; Chih-Hsin Hsu
Journal:  Intensive Care Med       Date:  2007-02-09       Impact factor: 17.440

5.  Performance of noninvasive ventilation modes on ICU ventilators during pressure support: a bench model study.

Authors:  Laurence Vignaux; Didier Tassaux; Philippe Jolliet
Journal:  Intensive Care Med       Date:  2007-06-12       Impact factor: 17.440

6.  A bench study of intensive-care-unit ventilators: new versus old and turbine-based versus compressed gas-based ventilators.

Authors:  Arnaud W Thille; Aissam Lyazidi; Jean-Christophe M Richard; Fabrice Galia; Laurent Brochard
Journal:  Intensive Care Med       Date:  2009-04-08       Impact factor: 17.440

7.  Patient-ventilator asynchrony during assisted mechanical ventilation.

Authors:  Arnaud W Thille; Pablo Rodriguez; Belen Cabello; François Lellouche; Laurent Brochard
Journal:  Intensive Care Med       Date:  2006-08-01       Impact factor: 17.440

Review 8.  [Non-invasive ventilation].

Authors:  T Köhnlein; T Welte
Journal:  Internist (Berl)       Date:  2006-09       Impact factor: 0.743

9.  Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

Authors:  Shinya Oda; Kei Otaki; Nozomi Yashima; Misato Kurota; Sachiko Matsushita; Airi Kumasaka; Hutaba Kurihara; Kaneyuki Kawamae
Journal:  J Anesth       Date:  2016-04-09       Impact factor: 2.078

10.  Mechanical ventilation and the total artificial heart: optimal ventilator trigger to avoid post-operative autocycling - a case series and literature review.

Authors:  Allen B Shoham; Bhavesh Patel; Francisco A Arabia; Michael J Murray
Journal:  J Cardiothorac Surg       Date:  2010-05-17       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.