Literature DB >> 9438429

Navigated single-voxel proton spectroscopy of the human liver.

J M Tyszka1, J M Silverman.   

Abstract

The addition of a navigator echo acquisition to a 1H spectroscopy sequence allows retrospective motion correction using acceptance criteria based on measured displacement of the diaphragm. This technique has been applied to the acquisition of short echo-time 1H spectroscopy of the liver in seven normal subjects. Navigation correction significantly improved overall spectral quality as measured by the phase variance, linewidth and suppression ratio of the water resonance. The hepatic choline resonance was consistently observed in all navigated spectra. Retrospective navigation makes close to optimal use of data acquisition time and, unlike external respiratory transducers, allows direct measurement of diaphragm displacement. The reconstruction of multiple voxel spectra from a single data set was also demonstrated.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9438429     DOI: 10.1002/mrm.1910390102

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  In vivo monitoring response to chemotherapy of human diffuse large B-cell lymphoma xenografts in SCID mice by 1H and 31P MRS.

Authors:  Ming Q Huang; David S Nelson; Stephen Pickup; Hui Qiao; E James Delikatny; Harish Poptani; Jerry D Glickson
Journal:  Acad Radiol       Date:  2007-12       Impact factor: 3.173

2.  Liver metabolite concentrations measured with 1H MR spectroscopy.

Authors:  Ronald Ouwerkerk; Roderic I Pettigrew; Ahmed M Gharib
Journal:  Radiology       Date:  2012-08-13       Impact factor: 11.105

3.  Breath-hold 1H-magnetic resonance spectroscopy for intrahepatic lipid quantification at 3 Tesla.

Authors:  Miriam A Bredella; Reza Hosseini Ghomi; Bijoy J Thomas; Hugue A Ouellette; Dushyant V Sahani; Karen K Miller; Martin Torriani
Journal:  J Comput Assist Tomogr       Date:  2010 May-Jun       Impact factor: 1.826

4.  Quantitative analysis of hepatic fat fraction by single-breath-holding MR spectroscopy with T₂ correction: phantom and clinical study with histologic assessment.

Authors:  Norio Hayashi; Tosiaki Miyati; Takashi Minami; Yumie Takeshita; Yasuji Ryu; Tsuyoshi Matsuda; Naoki Ohno; Takashi Hamaguchi; Kenichiro Kato; Toshinari Takamura; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2012-12-07

5.  Rigid-body motion correction with self-navigation MRI.

Authors:  Jason Mendes; Eugene Kholmovski; Dennis L Parker
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

6.  Gradient moment compensated magnetic resonance spectroscopic imaging.

Authors:  Dong-Hyun Kim; Meng Gu; Daniel M Spielman
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.