A filtration method for improving film dosimetry in photon radiation therapy.

I J Yeo1, C K Wang, S E Burch.   

Abstract

Successful radiotherapy requires accurate dosimetry for treatment verification. Existing dosimeters such as ion chambers, TLD, and diodes have drawbacks such as relatively long measurement time and poor spatial resolution. These disadvantages become serious problems for dynamic-wedged beams. Thus the clinical use of dynamic wedges requires an improved dosimetry method. X-ray film may serve this purpose. However, x-ray film is not clinically accepted as a dosimeter for photon beams, because it overresponds to photons with energies below about 400 keV. This paper presents and develops a method which was initially proposed by Burch to improve the dose response of x-ray film in a phantom. The method is based on placing high-atomic number foils next to the film. The foils are used as filters to preferentially remove low-energy photons. The optimal film and filter configuration in a phantom was determined using a mathematical scheme derived in this study and a Monte Carlo technique (ITS code). The optimal configuration thus determined is as follows: the filter-to-film distance of 6 mm and the filter thickness of 0.15 mm for percent depth-dose measurement; the distance of 1 cm and the thickness of 0.25 mm for off-axis (dose) ratio measurement. The configuration was then tested with photon beams from a 4 MV linac. The test result indicates that the in-phantom dose distribution based on the optimal configuration agrees well with those measured by ion chambers.

Mesh:

Substances:

Year:  1997        PMID: 9434977     DOI: 10.1118/1.598108

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

2.  Dosimetric verification of compensated beams using radiographic film.

Authors:  Slaven Jurkovic; Gordana Zauhar; Dario Faj; Deni Smilovic Radojcic; Manda Svabic; Mladen Kasabasic; Ana Diklic
Journal:  Radiol Oncol       Date:  2011-07-20       Impact factor: 2.991

3.  Evaluation of dose distribution of an intraoperative radiotherapy device using thermoluminescent dosimeters and radiographic films.

Authors:  Omid Baziar; Hamid Gholamhosseinian; Seyed Amir Aledavood; Mahboubeh Sadeghi
Journal:  Rep Pract Oncol Radiother       Date:  2022-07-29

4.  Comparison between measured and calculated dynamic wedge dose distributions using the anisotropic analytic algorithm and pencil-beam convolution.

Authors:  Paola Francisca Caprile; Carlos Daniel Venencia; Pelayo Besa
Journal:  J Appl Clin Med Phys       Date:  2006-08-08       Impact factor: 2.102

5.  Commissioning and quality assurance for intensity modulated radiotherapy with dynamic multileaf collimator: experience of the Pontificia Universidad Católica de Chile.

Authors:  Carlos Daniel Venencia; Pelayo Besa
Journal:  J Appl Clin Med Phys       Date:  2004-07-01       Impact factor: 2.102