Literature DB >> 9430545

Statistical aspects of the normal visual field in short-wavelength automated perimetry.

J M Wild1, R P Cubbidge, I E Pacey, R Robinson.   

Abstract

PURPOSE: To determine the intraindividual and interindividual characteristics of normal sensitivity derived by short-wavelength automated perimetry (SWAP) as a function of threshold algorithm. To determine also the influence of ocular media absorption on the magnitude of the interindividual variation in normal sensitivity, and hence the confidence limits, derived by SWAP.
METHODS: The sample comprised 51 normal subjects, stratified for age by decade (mean age, 55.5 years; range, 24-83 years) and experienced in white-on-white (W-W) perimetry and SWAP. One randomly assigned eye of each subject was examined on three occasions with Program 30-2 of the 640 Humphrey Field Analyzer using the Full Threshold and FASTPAC strategies for SWAP and W-W perimetries. Ocular media absorption (OMA) was assessed by the difference in scotopic sensitivity to stimuli of 410 and 560 nm.
RESULTS: The group mean examination time (P < 0.001) was greater for SWAP than for W-W perimetry for both the Full Threshold (15.0% longer) and FASTPAC strategies (16.8% longer). The gradient of the age-decline in Mean Sensitivity for SWAP was approximately 25% less steep when corrected for OMA than when uncorrected. The interindividual normal variability, expressed as the coefficient of variation, for SWAP without correction for OMA was 2.7 times greater (range 2.0-3.9), and with correction 1.9 times greater (range 1.4-2.9), than that for W-W perimetry.
CONCLUSIONS: The increased interindividual normal variability of SWAP, exacerbated by the lack of correction for OMA, currently limits the utility of SWAP in that the reduction in sensitivity required to indicate abnormality was proportionately greater than for W-W perimetry.

Mesh:

Year:  1998        PMID: 9430545

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  8 in total

Review 1.  Acquired colour vision defects in glaucoma-their detection and clinical significance.

Authors:  M Pacheco-Cutillas; D F Edgar; A Sahraie
Journal:  Br J Ophthalmol       Date:  1999-12       Impact factor: 4.638

2.  Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.

Authors:  J Landers; A Sharma; I Goldberg; S Graham
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

Review 3.  Detection and measurement of clinically meaningful visual field progression in clinical trials for glaucoma.

Authors:  C Gustavo De Moraes; Jeffrey M Liebmann; Leonard A Levin
Journal:  Prog Retin Eye Res       Date:  2016-10-20       Impact factor: 21.198

Review 4.  Diagnostic tools for glaucoma detection and management.

Authors:  Pooja Sharma; Pamela A Sample; Linda M Zangwill; Joel S Schuman
Journal:  Surv Ophthalmol       Date:  2008-11       Impact factor: 6.048

5.  Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects.

Authors:  Chintan Malhotra
Journal:  Oman J Ophthalmol       Date:  2009-01

6.  Quantification of visual field loss in age-related macular degeneration.

Authors:  Jennifer H Acton; Jonathan M Gibson; Robert P Cubbidge
Journal:  PLoS One       Date:  2012-06-29       Impact factor: 3.240

7.  Individual Colorimetric Observer Model.

Authors:  Yuta Asano; Mark D Fairchild; Laurent Blondé
Journal:  PLoS One       Date:  2016-02-10       Impact factor: 3.240

8.  Cardiac Hypertrophy May Be a Risk Factor for the Development and Severity of Glaucoma.

Authors:  Yukihisa Suzuki; Motohiro Kiyosawa
Journal:  Biomedicines       Date:  2022-03-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.