Literature DB >> 16361671

Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.

J Landers1, A Sharma, I Goldberg, S Graham.   

Abstract

BACKGROUND: Traquair described the topography of visual field sensitivity as a "hill" or "island" of vision. Achromatic automated perimetry (AAP) demonstrates this shape of the visual field in photopic conditions. Techniques claimed to target the magnocellular pathway (frequency doubling perimetry, FDP) and those using a stimulus targeting the koniocellular pathway (short wavelength (or blue on yellow) automated perimetry, SWAP), might produce one that is different. The authors compared the visual field topography from FDP with those of SWAP and AAP, to investigate whether there were significant differences in their shape.
METHOD: A sample of 51 patients with previously confirmed normal perimetry were recruited; either low risk glaucoma suspects or normal controls. AAP, SWAP, and FDP perimetry was performed in random order on the same day. The topography of each field was analysed to determine its average shape and to compare results in the same individuals.
RESULTS: The topography of the visual field produced by each perimeter differed significantly. While all three had maximal sensitivity centrally, over the 24 degrees from the centre to the periphery, mean sensitivities decreased by 4.9 decibels (dB) for AAP and 7.3 dB for SWAP, while FDP sensitivities by just 1.8 dB over 20 degrees (the extent of the FDP field). FDP mean sensitivities decreased by approximately 0.3 dB with every 10 year increase in age, compared with 1 dB for AAP and 2 dB for SWAP.
CONCLUSION: While the topography of the SWAP (koniocellular) field is steeper than corresponding AAP fields, that of the FDP (magnocellular) visual field was considerably flatter. The difference in this shape may reflect retinotopic or cortical mechanisms, which are specific to the magnocellular pathways.

Entities:  

Mesh:

Year:  2006        PMID: 16361671      PMCID: PMC1856911          DOI: 10.1136/bjo.2005.071266

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  25 in total

Review 1.  The definition and classification of glaucoma in prevalence surveys.

Authors:  Paul J Foster; Ralf Buhrmann; Harry A Quigley; Gordon J Johnson
Journal:  Br J Ophthalmol       Date:  2002-02       Impact factor: 4.638

2.  An examination of physiological mechanisms underlying the frequency-doubling illusion.

Authors:  Andrew J R White; Hao Sun; William H Swanson; Barry B Lee
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-11       Impact factor: 4.799

3.  Visual field of high-pass resolution perimetry in normal subjects.

Authors:  Michael Wall; Balwantray Chauhan; Lars Frisén; Philip H House; Caridad Brito
Journal:  J Glaucoma       Date:  2004-02       Impact factor: 2.503

4.  [ON THE RELATION BETWEEN LIGHT SENSE AND VISUAL ACUITY].

Authors:  E AULHORN
Journal:  Albrecht Von Graefes Arch Ophthalmol       Date:  1964-03-03

5.  Functional properties of ganglion cells of the rhesus monkey retina.

Authors:  F M De Monasterio; P Gouras
Journal:  J Physiol       Date:  1975-09       Impact factor: 5.182

6.  The representation of the visual field in parvicellular and magnocellular layers of the lateral geniculate nucleus in the macaque monkey.

Authors:  M Connolly; D Van Essen
Journal:  J Comp Neurol       Date:  1984-07-10       Impact factor: 3.215

7.  Effects of target size and eccentricity on visual detection and resolution.

Authors:  C A Johnson; J L Keltner; F Balestrery
Journal:  Vision Res       Date:  1978       Impact factor: 1.886

8.  Static and kinetic visual field testing. Reproducibility in normal volunteers.

Authors:  R K Parrish; J Schiffman; D R Anderson
Journal:  Arch Ophthalmol       Date:  1984-10

9.  Variability of the hill of vision and its significance in automated perimetry.

Authors:  N A Jacobs; I H Patterson
Journal:  Br J Ophthalmol       Date:  1985-11       Impact factor: 4.638

10.  X and Y cells in the lateral geniculate nucleus of macaque monkeys.

Authors:  E Kaplan; R M Shapley
Journal:  J Physiol       Date:  1982-09       Impact factor: 5.182

View more
  3 in total

1.  Combining Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry for Glaucoma Detection.

Authors:  Jean-Claude Mwanza; Joshua L Warren; Jessica T Hochberg; Donald L Budenz; Robert T Chang; Pradeep Y Ramulu
Journal:  J Glaucoma       Date:  2015 Oct-Nov       Impact factor: 2.503

2.  The Psychophysical Assessment of Hierarchical Magno-, Parvo- and Konio-Cellular Visual Stream Dysregulations in Migraineurs.

Authors:  Michael F Wesner; James Brazeau
Journal:  Eye Brain       Date:  2019-11-29

3.  Structure-Function Relationship in Glaucoma Patients With Parafoveal Versus Peripheral Nasal Scotoma.

Authors:  Kyoung In Jung; Min Ku Kang; Jin A Choi; Hye-Young Shin; Chan Kee Park
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-02       Impact factor: 4.799

  3 in total