Flow versus uptake comparisons of thallium-201 with technetium-99m perfusion tracers in a canine model of myocardial ischemia.

M J Meleca1, A J McGoron, M C Gerson, R W Millard, M Gabel, D Biniakiewicz, N J Roszell, R A Walsh.   

Abstract

UNLABELLED: We investigated the myocardial flow kinetics of six putative radioperfusion agents (99mTc-Q3, 99mTc-Q4, 99mTc-Q12, 99mTc-sestamibi, 99mTc-tetrofosmin and 99mTcN-NOET) and 201Tl in a canine model of myocardial ischemia with pharmacologic coronary artery vasodilation.
METHODS: In 31 open-chest dogs with acute coronary occlusion, dipyridamole (approximately 0.56 mg/kg) was infused intravenously, followed by a perfusion tracer injection and radioactive microspheres for myocardial blood flow (MBF) measurement. The paired data were normalized using three techniques; average, normal or maximum myocardial tracer activity and MBF.
RESULTS: The upper limit of MBF obtained for the group of tracers ranged from 4.2 ml/min/g to 8.2 ml/min/g. There was a statistically significant (p < 0.0001) linear correlation (r = 0.87-0.98) between the normalized myocardial activity and the normalized MBF values of each of the tracers. The slope of the curve normalized by average for 201Tl (0.83) was greater than those for the 99mTc tracers, and the intercept (0.07) was lower than those for the 99mTc tracers. Slopes and intercepts for the 99mTc agents were as follows: 99mTc-Q3, 0.81 and 0.18; 99mTc-Q4, 0.61 and 0.41; 99mTc-Q12, 0.63 and 0.39; 99mTc-sestamibi, 0.62 and 0.34; 99mTc-tetrofosmin, 0.68 and 0.32; and 99mTcN-NOET, 0.71 and 0.29, respectively.
CONCLUSION: In an anesthetized open-chest canine model of regional myocardial ischemia with dipyridamole induced hyperemia, 201Tl shows a more ideal relationship between tracer uptake and MBF than do the 99mTc-based agents. Of the various 99mTc-based imaging agents studied, the myocardial flow kinetics of 99mTc-Q3 appear to be closest to ideal. This relationship is maintained regardless of the normalization technique used. This may, in theory, imply a higher sensitivity in discerning ischemic from normal myocardium and a role in diagnostic nuclear imaging for 99mTc-Q3.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9430457

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

1.  Proceedings of the 4th Invitational Wintergreen Conference. Wintergreen, Virginia, USA. July 12-14, 1998. Abstracts.

Authors: 
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

Review 2.  Experimental evaluation of radiotracers: role of intact biological models.

Authors:  A J Sinusas
Journal:  J Nucl Cardiol       Date:  1998 Mar-Apr       Impact factor: 5.952

3.  Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography: comparison with static thallium-201 in a canine model.

Authors:  E V Di Bella; S G Ross; D J Kadrmas; H S Khare; P E Christian; S McJames; A G Gullberg
Journal:  Invest Radiol       Date:  2001-03       Impact factor: 6.016

4.  Comparison of exercise, dipyridamole, adenosine, and dobutamine stress with the use of Tc-99m tetrofosmin tomographic imaging.

Authors:  M G Levine; A W Ahlberg; A Mann; M P White; C C McGill; C Mendes de Leon; J M Piriz; D Waters; G V Heller
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

5.  Comparison of Static and Dynamic Cardiac Perfusion Thallium-201 SPECT.

Authors:  Harshali S Khare; Edward V R Dibella; Dan J Kadrmas; Paul E Christian; Grant T Gullberg
Journal:  IEEE Trans Nucl Sci       Date:  2001-06       Impact factor: 1.679

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.