Evaluation of lipid profile measurements obtained from the Cholestech L.D.X analyzer.

R L Bard1, L A Kaminsky, M H Whaley, S Zajakowski.   

Abstract

BACKGROUND: The Cholestech L.D.X analyzer has the capability of performing a lipid profile in approximately 5 minutes. The purpose of this study was to determine analytical performance capability of the L.D.X to perform lipid profile measurements.
METHODS: Forty subjects gave two finger capillary samples and one venous serum which were analyzed in duplicate by two technicians, on two different L.D.X analyzers. A local pathology laboratory was used as the standard for accuracy comparisons. Two controls with known values were provided by the manufacturer to assess within-day precision. Day-to-day precision was determined by analyzing high (240 mg/dL-1 total cholesterol (TC) and 60 mg/dL-1 high-density lipoprotein [HDL]) and low (200 mg/dL-1 TC and 35 mg/dL-1 HDL) human serum samples on 10 different days.
RESULTS: Analysis of variance procedures revealed no significant differences between the two technicians or the two analyzers, nor among the fingerstick, venous serum, or reference measures for any of the analytes. The total error of measurement of TC, triglycerides, and HDL measurements were 6.3 to 16.2%, 14.8 to 30.8%, and 11.5 to 26.8%, respectively. In comparison to the National Cholesterol Education Program (NCEP) desirable, borderline-high, and high classifications obtained from the reference laboratory the L.D.X TC results were correctly classified in 92.5% of the cases. L.D.X triglyceride classifications of desirable, borderline hypertyglyceridemia, and distinct hypertriglyceridemia matched 100% with the classifications obtained from the reference laboratory.
CONCLUSIONS: Although the Cholestech L.D.X analyzer did not consistently meet NCEP standards for acceptable total measurement error of TC, HDL, and triglyceride analyses, it seems capable of providing reasonable lipid profile measures in both a screening setting and a clinician office where the goal is correct classification of patients' results.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9421763     DOI: 10.1097/00008483-199711000-00005

Source DB:  PubMed          Journal:  J Cardiopulm Rehabil        ISSN: 0883-9212            Impact factor:   2.081


  7 in total

1.  Rationale, design, and baseline characteristics of a community-based comparative effectiveness trial to prevent type 2 diabetes in economically disadvantaged adults: the RAPID Study.

Authors:  Ronald T Ackermann; Emily A Finch; Karen K Schmidt; Helena M Hoen; Laura M Hays; David G Marrero; Chandan Saha
Journal:  Contemp Clin Trials       Date:  2013-10-29       Impact factor: 2.226

2.  A Randomized Comparative Effectiveness Trial for Preventing Type 2 Diabetes.

Authors:  Ronald T Ackermann; David T Liss; Emily A Finch; Karen K Schmidt; Laura M Hays; David G Marrero; Chandan Saha
Journal:  Am J Public Health       Date:  2015-09-17       Impact factor: 9.308

3.  Lifestyle and psychosocial risk factors predict non-adherence to medication.

Authors:  Brooke Aggarwal; Lori Mosca
Journal:  Ann Behav Med       Date:  2010-10

4.  Clinical utility of a fingerstick technology to identify individuals with abnormal blood lipids and high-sensitivity C-reactive protein levels.

Authors:  Parin Parikh; Heidi Mochari; Lori Mosca
Journal:  Am J Health Promot       Date:  2009 Mar-Apr

5.  Translating the Diabetes Prevention Program into the community. The DEPLOY Pilot Study.

Authors:  Ronald T Ackermann; Emily A Finch; Edward Brizendine; Honghong Zhou; David G Marrero
Journal:  Am J Prev Med       Date:  2008-10       Impact factor: 5.043

6.  Reduced 10-year risk of coronary heart disease in patients who participated in a community-based diabetes prevention program: the DEPLOY pilot study.

Authors:  Elaine R Lipscomb; Emily A Finch; Edward Brizendine; Chandan K Saha; Laura M Hays; Ronald T Ackermann
Journal:  Diabetes Care       Date:  2008-12-23       Impact factor: 19.112

7.  Increased presence of oxidized low-density lipoprotein in the left ventricular blood of subjects with cardiovascular disease.

Authors:  Chandrakala Aluganti Narasimhulu; Dmitry Litvinov; Bhaswati Sengupta; Danielle Jones; Chittoor Sai-Sudhakar; Michael Firstenberg; Benjamin Sun; Sampath Parthasarathy
Journal:  Physiol Rep       Date:  2016-03-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.