Biomechanical comparison of fixation methods in transverse olecranon fractures: a cadaveric study.

M J Prayson1, J L Williams, M P Marshall, T A Scilaris, E J Lingenfelter.   

Abstract

OBJECTIVES/HYPOTHESIS: Our null hypothesis was that no difference in fracture displacement would be detected between traditional monofilament wire and Kirschner wire placement versus three modified tension-band techniques for transverse olecranon fractures. STUDY
DESIGN: A nested form of the repeated measures design with twenty-two paired embalmed elbows (subjects grouped by sex and nested within the fracture method).
METHODS: Transverse osteotomies were created at the olecranon and stabilized with four techniques. One hundred cycles of loading were applied to achieve a peak flexion bending moment at the fracture of nine newton-meters. At the onset of testing, the triceps tendon was anchored at an initial elbow flexion angle of 70 degrees.
RESULTS: When using a monofilament figure-eight loop, oblique Kirschner wire placement into the anterior ulnar cortex provided greater resistance to tensile force than intramedullary Kirschner wires (p = 0.04). With intramedullary Kirschner wire placement, 1.6-millimeter-diameter braided cable in both figure-eight (p < 0.0001) and circular loop (p < 0.0001) designs allowed less fracture displacement than did the 1.0-millimeter-diameter monofilament wire. There was no difference between figure-eight and circular loop configurations when using braided cable (p = 0.98).
CONCLUSIONS: In transverse noncomminuted olecranon fractures, fixation with monofilament wire is superior with Kirschner wire placement into the anterior ulnar cortex. With intramedullary Kirschner wires, fixation using braided cable is significantly improved over that with monofilament wire. When using braided cable, figure-eight and circular loop designs allow similar displacements. Braided cable or anterior cortical Kirschner wire purchase increases the stability of fixation over that achieved with the traditional method.

Entities:  

Mesh:

Year:  1997        PMID: 9415862     DOI: 10.1097/00005131-199711000-00004

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  7 in total

1.  Complication rate and factors affecting outcome of olecranon osteotomies repaired with pin and tension-band fixation in dogs.

Authors:  Krista B Halling; Daniel D Lewis; Alan R Cross; Sharon C Kerwin; Bruce A Smith; Paul S Kubilis
Journal:  Can Vet J       Date:  2002-07       Impact factor: 1.008

2.  CORR Insights(®): Factors Associated with Reoperation after Fixation of Displaced Olecranon Fractures.

Authors:  Nash H Naam
Journal:  Clin Orthop Relat Res       Date:  2015-09-11       Impact factor: 4.176

3.  [Olecranon osteotomy].

Authors:  R Meier; F Gohlke
Journal:  Orthopade       Date:  2013-05       Impact factor: 1.087

4.  Olecranon tension plating or olecranon tension band wiring? A comparative biomechanical study.

Authors:  Dominik Gruszka; Charlotte Arand; Tobias Nowak; Sven-Oliver Dietz; Daniel Wagner; Pol Rommens
Journal:  Int Orthop       Date:  2015-02-25       Impact factor: 3.075

5.  Factors Associated With Reoperation After Fixation of Displaced Olecranon Fractures.

Authors:  Femke M A P Claessen; Yvonne Braun; Rinne M Peters; George Dyer; Job N Doornberg; David Ring
Journal:  Clin Orthop Relat Res       Date:  2015-08-07       Impact factor: 4.176

6.  Biomechanical properties of an intramedullary suture anchor fixation compared to tension band wiring in osteoporotic olecranon fractures- A cadaveric study.

Authors:  Arvind von Keudell; Amir Kachooei; Amin Mohamadi; Sharri J Mortensen; Stephen Okajima; Jonathan Egan; MichaelJ Weaver; George S M Dyer; Ara Nazarian
Journal:  J Orthop       Date:  2019-08-07

7.  Clinical results of the re-fixation of a Chevron olecranon osteotomy using an intramedullary cancellous screw and suture tension band.

Authors:  Marc L Wagener; Marleen Dezillie; Yvette Hoendervangers; Denise Eygendaal
Journal:  Strategies Trauma Limb Reconstr       Date:  2015-02-20
  7 in total